MétaCan
Menu
Back to cohort
Record W2318366523 · doi:10.1021/la501102x

Quantum Dot-Based Multidonor Concentric FRET System and Its Application to Biosensing Using an Excitation Ratio

2014· article· en· W2318366523 on OpenAlexafffund
Hyungki Kim, Cheryl Y.W. Ng, W. Russ Algar

Bibliographic record

VenueLangmuir · 2014
Typearticle
Languageen
FieldMaterials Science
TopicQuantum Dots Synthesis And Properties
Canadian institutionsUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of British ColumbiaCanada Research Chairs
KeywordsBiosensorFörster resonance energy transferQuantum dotExcitationChemistryNanotechnologyConcentricAnalytical Chemistry (journal)Materials scienceFluorescenceChromatographyPhysicsOpticsQuantum mechanicsMathematics

Abstract

fetched live from OpenAlex

A plethora of semiconductor quantum dot (QD)-based probes that rely on Förster resonance energy transfer (FRET) have been developed for the optical detection of a wide array of biological targets. To date, the vast majority of these probes have utilized one-step energy transfer between individual donor-acceptor pairs. Here, we report a new multidonor concentric FRET configuration that comprised two fluorescent dyes assembled around a central CdSeS/ZnS QD through peptide linkers. One of these dyes, either Alexa Fluor 555 (A555) or Alexa Fluor 647 (A647), served as an acceptor for both the central QD and the other coassembled dye, Alexa Fluor 488 (A488). The unresolved emission between the A488 and the QD precluded a standard analysis of FRET efficiency from quenching of donor emission intensity or decay time, instead necessitating an analysis of the two energy transfer pathways from deconvolved excitation spectra. When A647 was the terminal acceptor, both the QD-to-A647 and A488-to-A647 energy transfer pathways could be interrogated with blue light, but only the former could be interrogated with violet light. The different degrees of A647 sensitization between these two excitation wavelengths was a predictable function of the above energy transfer efficiencies and dye stoichiometry, and was exploited for quantitative bioanalysis through an excitation ratio, which is in contrast to the conventional use of an emission ratio with FRET-based probes. Detection of the activity of nanomolar concentrations of trypsin, a model protease that hydrolyzed the A488-labeled peptide linker, was demonstrated using both a fluorescence plate reader and a low-cost, compact device that used two low-power light-emitting diodes (LEDs) as excitation sources and a silicon photodiode to detect A647 emission. This multidonor concentric FRET configuration represents a new modality for ratiometric biosensing with QDs and is potentially useful for portable in vitro diagnostics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.563
Threshold uncertainty score0.353

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.259
Teacher spread0.225 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueLangmuirSame topicQuantum Dots Synthesis And PropertiesFrench-language works237,207