Record W2318630663 · doi:10.1177/0954411914567930

The biochemical characteristics of wear testing lubricants affect polyethylene wear in orthopaedic pin-on-disc testing

2015· article· en· W2318630663 on OpenAlexaff
Leah E Guenther, Thomas R. Turgeon, Éric Bohm, Jan-M. Brandt

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2015
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsConcordia HospitalUniversity of Manitoba
Fundersnot available
KeywordsLubricantHyaluronic acidPolyethyleneMaterials sciencePhosphate buffered salineSalineDry lubricantPhosphateThermal stabilityBiomedical engineeringComposite materialChromatographyChemistryMedicineBiochemistryOrganic chemistry

Abstract

fetched live from OpenAlex

Lubricant protein concentration is known to affect crosslinked polyethylene wear in in vitro testing; however, the biochemical nature of these lubricants may also have a significant effect on wear and dictate its clinical relevance. A modified approach to pin-on-disc testing was implemented to explore the effect of four biochemically different lubricants on the wear of two types of crosslinked polyethylene materials (XLK™ and Marathon™; DePuy Synthes, Warsaw, IN, USA). XLK was associated with higher wear rates than Marathon. In comparison to lubricants containing deionized water, lubricants containing phosphate buffered saline solution and hyaluronic acid increased osmolality by up to 1.2 times and thermal stability by up to 1.4 times. This biochemical change reduced wear by up to 12.5 times. Wear rates for XLK and Marathon differed by a factor of 3.2 using lubricants with phosphate buffered saline solution as the dilutive media, but only 2.0 for lubricants with deionized water. Interestingly, varying the concentration of hyaluronic acid did not have a significant effect on wear, and differences between XLK and Marathon wear rates were not found to be statistically significant when hyaluronic acid was added to the lubricant. The findings of this study showed that increasing the osmolality and thermal stability of lubricants to more clinical levels decreased wear; however, the effect of hyaluronic acid on wear may not be apparent in simplistic pin-on-disc testing. It was suggested that phosphate buffered saline solution be used as the dilutive media of choice in order to better differentiate the ranking of materials while maintaining some clinical relevance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.262
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicOrthopaedic implants and arthroplastyFrench-language works237,207