MétaCan
Menu
Back to cohort
Record W2319689108 · doi:10.1097/bcr.0000000000000207

Peripherally Inserted Central Venous Catheter Safety in Burn Care

2014· article· en· W2319689108 on OpenAlexaff
Ryan E Austin, Shahriar Shahrokhi, Siavash Bolourani, Marc G. Jeschke

Bibliographic record

VenueJournal of Burn Care & Research · 2014
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsUniversity of TorontoHealth Sciences CentreSunnybrook Health Science Centre
FundersNational Institute of General Medical Sciences
KeywordsMedicinePeripherally inserted central catheterDiscontinuationComplicationCatheterCentral lineThrombosisSurgeryRetrospective cohort studyVenous thrombosisDeep veinIntensive care unitEmergency medicineIntensive care medicine

Abstract

fetched live from OpenAlex

The use of peripherally inserted central catheter (PICC) line for central venous access in thermally injured patients has increased in recent years despite a lack of evidence regarding safety in this patient population. A recent survey of invasive catheter practices among 44 burn centers in the United States found that 37% of burn units use PICC lines as part of their treatment protocol. The goal of this study was to compare PICC-associated complication rates with the existing literature in both the critical care and burn settings. The methodology involved is a single institution retrospective cohort review of patients who received a PICC line during admission to a regional burn unit between 2008 and 2013. Fifty-three patients were identified with a total of seventy-three PICC lines. The primary outcome measurement for this study was indication for PICC line discontinuation. The most common reason for PICC line discontinuation was that the line was no longer indicated (45.2%). Four cases of symptomatic upper extremity deep vein thrombosis (5.5%) and three cases of central line-associated bloodstream infection (4.3%, 2.72 infections per 1000 line days) were identified. PICC lines were in situ an average of 15 days (range 1 to 49 days). We suggest that PICC line-associated complication rates are similar to those published in the critical care literature. Though these rates are higher than those published in the burn literature, they are similar to central venous catheter-associated complication rates. While PICC lines can be a useful resource in the treatment of the thermally injured patient, they are associated with significant and potentially fatal risks.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesResearch integrity
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Qualitative · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.395
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.003
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.054
GPT teacher head0.412
Teacher spread0.358 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designQualitative
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Burn Care & ResearchSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207