MétaCan
Menu
Back to cohort
Record W2319983576 · doi:10.1097/brs.0000000000000211

In Vivo Study of a Self-Stabilizing Artificial Vertebral Body Fabricated by Electron Beam Melting

2014· article· en· W2319983576 on OpenAlexaff
Jun Yang, Hong Cai, Jia Lv, Ke Zhang, Huijie Leng, Chuiguo Sun, Zhiguo Wang, Zhongjun Liu

Bibliographic record

VenueSpine · 2014
Typearticle
Languageen
FieldEngineering
TopicBone Tissue Engineering Materials
Canadian institutionsDiscovery Air (Canada)
Fundersnot available
KeywordsMedicineVertebral bodyImplantCorpectomySpinal fusionSurgeryCervical vertebraeBiomedical engineeringArtificial boneBiomechanicsCervical spineAnatomy

Abstract

fetched live from OpenAlex

In Brief Study Design. In vivo assessment of a novel artificial vertebral body fabricated by electron beam melting (EBM) for cervical vertebral body replacement in a sheep model. Objective. To investigate the feasibility of a novel artificial vertebral body: a “self-stabilizing artificial vertebral body” (SSAVB) fabricated by EBM in a sheep model. Summary of Background Data. Artificial vertebral body is widely used for vertebral body replacement and spinal fusion, but research on an artificial vertebral body fabricated by EBM has not been reported. Methods. An SSAVB made of porous Ti6Al4V was implanted into a sheep cervical spine to replace the C4 vertebral body for 6 and 12 weeks. Bone ingrowth and implant stability were radiologically evaluated, and histological and biomechanical tests were performed. Results. No screw loosening, implant dislocation, or bone fractures occurred during the experimental period. A significant difference (P = 0.001) in bone ingrowth between the 6- and 12-week groups was noted. Comparison of the range of motion of C3–C5 segments between the in vivo group and the control groups (intact C2–C6 segment and fresh sheep cervical spines from C2 to C6 segments that underwent C4 subtotal corpectomy with the posterior vertebral wall retention by SSAVB implantation) suggests that the implant can stably replace this area of the cervical spine. Conclusion. The open porous structure of Ti6Al4V fabricated by EBM facilitated bone ingrowth and the SSAVB can maintain cervical spine stability of the sheep. A porous metal implant can be used for load-bearing applications in a sheep model. It is hoped that these results will stimulate further study in human. Level of Evidence: 4 To date, research-related experiments on artificial vertebral body fabricated by electron beam melting (EBM) has not been reported. This article investigates the feasibility of a novel artificial vertebral body without an additional anterior plate or a posterior internal fixation named self-stabilizing artificial vertebral body fabricated by EBM in a sheep model.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.215
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations100
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicBone Tissue Engineering MaterialsFrench-language works237,207