In Vivo Study of a Self-Stabilizing Artificial Vertebral Body Fabricated by Electron Beam Melting
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
In Brief Study Design. In vivo assessment of a novel artificial vertebral body fabricated by electron beam melting (EBM) for cervical vertebral body replacement in a sheep model. Objective. To investigate the feasibility of a novel artificial vertebral body: a “self-stabilizing artificial vertebral body” (SSAVB) fabricated by EBM in a sheep model. Summary of Background Data. Artificial vertebral body is widely used for vertebral body replacement and spinal fusion, but research on an artificial vertebral body fabricated by EBM has not been reported. Methods. An SSAVB made of porous Ti6Al4V was implanted into a sheep cervical spine to replace the C4 vertebral body for 6 and 12 weeks. Bone ingrowth and implant stability were radiologically evaluated, and histological and biomechanical tests were performed. Results. No screw loosening, implant dislocation, or bone fractures occurred during the experimental period. A significant difference (P = 0.001) in bone ingrowth between the 6- and 12-week groups was noted. Comparison of the range of motion of C3–C5 segments between the in vivo group and the control groups (intact C2–C6 segment and fresh sheep cervical spines from C2 to C6 segments that underwent C4 subtotal corpectomy with the posterior vertebral wall retention by SSAVB implantation) suggests that the implant can stably replace this area of the cervical spine. Conclusion. The open porous structure of Ti6Al4V fabricated by EBM facilitated bone ingrowth and the SSAVB can maintain cervical spine stability of the sheep. A porous metal implant can be used for load-bearing applications in a sheep model. It is hoped that these results will stimulate further study in human. Level of Evidence: 4 To date, research-related experiments on artificial vertebral body fabricated by electron beam melting (EBM) has not been reported. This article investigates the feasibility of a novel artificial vertebral body without an additional anterior plate or a posterior internal fixation named self-stabilizing artificial vertebral body fabricated by EBM in a sheep model.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it