MétaCan
Menu
Back to cohort
Record W2320242416 · doi:10.1177/0954411911412465

Reduced stress shielding with limited micromotions using a carbon fibre composite biomimetic hip stem: a finite element model

2011· article· en· W2320242416 on OpenAlexafffund
Christiane Caouette, L’H. Yahia, Martin Bureau

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2011
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsNational Research Council CanadaPolytechnique Montréal
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsStress shieldingFinite element methodMaterials scienceComposite numberElectromagnetic shieldingComposite materialStress (linguistics)Structural engineeringEngineeringMedicineSurgeryImplant

Abstract

fetched live from OpenAlex

Total hip arthroplasty (THA) enjoys excellent rates of success in older patients, but younger patients are still at risk of aseptic loosening and bone resorption from stress shielding. One solution to the stress shielding problem is to use a hip stem with mechanical properties matching those of cortical bone. The objective of the present study was to investigate numerically the biomechanical performance of such a biomimetic hip stem based on a hydroxyapatite (HA)-coated carbon fibre composite. A finite element model (FEM) of the biomimetic stem was constructed. Contact elements were studied to model the bone-implant interface in a non-osseointegrated and osseointegrated state in the best way. Three static load cases representing slow walking, stair climbing, and gait in a healthy individual were considered. Stress shielding and bone-implant interface micromotions were evaluated and compared with the results of a similar FEM based on titanium alloy (Ti-6Al-4V). The composite stems allowed for reduced stress shielding when compared with a traditional Ti-6Al-4V stem. Micromotions were slightly higher with the composite stem, but remained below 40 microm on most of the HA-coated surface. It is concluded that a biomimetic composite stem might offer a better compromise between stress shielding and micromotions than the Ti-6Al-4V stem with the same external geometry.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.243
Teacher spread0.202 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicOrthopaedic implants and arthroplastyFrench-language works237,207