MétaCan
Menu
Back to cohort
Record W2320772104 · doi:10.1097/mbp.0000000000000067

The effect of orthostatic stress type on cardiovascular control

2014· article· en· W2320772104 on OpenAlexafffund
Brett H. Shaw, Thomas M. Loughin, Dawn C. Mackey, Stephen N. Robinovitch, Victoria E. Claydon

Bibliographic record

VenueBlood Pressure Monitoring · 2014
Typearticle
Languageen
FieldMedicine
TopicCardiovascular Syncope and Autonomic Disorders
Canadian institutionsVancouver Coastal Health Research InstituteVancouver Coastal HealthSimon Fraser University
FundersHeart and Stroke Foundation of Canada
KeywordsMedicineBlood pressureHeart rateOrthostatic vital signsHemodynamicsStroke volumeCardiologyInternal medicineCold pressor testAnesthesia

Abstract

fetched live from OpenAlex

OBJECTIVES: We aimed to compare the cardiovascular responses of a novel orthostatic stress test, the passive seated orthostatic stress test (PSOST), with those during passive head-up tilt testing (HUTT). We hypothesized that cardiovascular responses during PSOST would be similar to those during HUTT (the 'gold standard'). METHODS: We tested 15 healthy volunteers, who underwent both PSOST and HUTT during one session in a random order. We measured beat-to-beat blood pressure, heart rate, peripheral resistance, stroke volume, cardiac output, and middle cerebral artery blood flow velocity during each test. RESULTS: Blood pressure responses were not significantly different between PSOST and HUTT, except for a significantly lower delayed nadir and 15-min recovery value in systolic arterial pressure during HUTT. HUTT elicited a significantly larger increase in heart rate during all test intervals in comparison with PSOST, as well as a larger decline in stroke volume during almost all test intervals. Responses for the other hemodynamic variables were not significantly different between the tests at any test interval. Repeated HUTT has large inherent variability, which was also evident from the variability in the mean differences on comparing PSOST and HUTT. There was a significant bias for larger heart rate increases (P<0.01) and a greater delayed systolic arterial pressure decline during HUTT. CONCLUSION: We have shown that PSOST and HUTT elicit similar blood pressure and cerebrovascular responses in the early stages of the upright phase. We believe that PSOST is a reasonable surrogate for HUTT in assessing orthostatic hypotension in population groups that are unable to stand for prolonged periods of time.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.220
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueBlood Pressure MonitoringSame topicCardiovascular Syncope and Autonomic DisordersFrench-language works237,207