MétaCan
Menu
Back to cohort
Record W2321512232 · doi:10.1097/brs.0000000000001200

Pedicle Screw Fixation Under Nonaxial Loads

2015· article· en· W2321512232 on OpenAlexaff
Rohan‐Jean Bianco, Carl‐Éric Aubin, Jean‐Marc Mac‐Thiong, Éric Wagnac, Pierre‐Jean Arnoux

Bibliographic record

VenueSpine · 2015
Typearticle
Languageen
FieldMedicine
TopicSpinal Fractures and Fixation Techniques
Canadian institutionsUniversité de MontréalPolytechnique Montréal
Fundersnot available
KeywordsCadaveric spasmBiomechanicsFixation (population genetics)Sagittal planeStiffnessOrthodonticsThread (computing)LumbarMaterials scienceScrew axisTransverse planeScrew threadMedicineAnatomyComposite materialComputer scienceMathematics

Abstract

fetched live from OpenAlex

STUDY DESIGN: An experimental study of pedicle screw fixation in human cadaveric vertebrae. OBJECTIVE: The aim of this study was to experimentally characterize pedicle screw fixation under nonaxial loading and to analyze the effect of the surgeons' screw and placement choices on the fixation risk of failure. SUMMARY OF BACKGROUND DATA: Pedicle screw fixation performance is traditionally characterized with axial pullout tests, which do not fully represent the various tridimensional loads sustained by the screws during correction maneuvers of severe spinal deformities. Previous studies have analyzed the biomechanics of nonaxial loads on pedicle screws, but their effects on the screw loosening mechanisms are still not well understood. METHODS: A design of experiment (DOE) approach was used to evaluate 2 screw thread designs (single-lead and dual-lead threads), 2 insertion trajectories in the transverse and sagittal planes, and 2 loading directions (lateral and cranial). Pedicle screws were inserted in both pedicles of 12 cadaveric lumbar vertebrae for a total of 24 tests. Four sinewave loading cycles (0-400 N) were applied, orthogonally to the screw axis, at the screw head. The resulting forces, displacements, and rotations of the screws were recorded. RESULTS: In comparison to the other cycles, the first loading cycle revealed important permanent deformation of the bone (mean permanent displacement of the screw head of 0.79 mm), which gradually accumulated over the following cycles to 1.75 mm on average (plowing effect). The cranial loading direction caused significantly lower (P < 0.05) bone deformation than lateral loading. The dual-lead screw had a significantly higher (P < 0.05) initial stiffness than the single-lead thread screw. CONCLUSIONS: Nonaxial loads induce screw plowing that lead to bone compacting and subsequent screw loosening or even bone failure, thus reducing the pedicle screw fixation strength. Lateral loads induce greater bone deformation and risks of failure than cranial loads. LEVEL OF EVIDENCE: N/A.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.514
Threshold uncertainty score0.365

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.049
GPT teacher head0.344
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicSpinal Fractures and Fixation TechniquesFrench-language works237,207