MétaCan
Menu
Back to cohort
Record W2321925611 · doi:10.1097/mnm.0b013e32836529ab

Development of a modified sampling and calculation method for isotope plasma clearance assessment of the glomerular filtration rate in patients with cirrhosis and ascites

2013· article· en· W2321925611 on OpenAlexaff
Fred Wickham, Maria Burniston, Elias Xirouchakis, Eleni Theocharidou, Carl A. Wesolowski, A. J.W. Hilson, Andrew K. Burroughs

Bibliographic record

VenueNuclear Medicine Communications · 2013
Typearticle
Languageen
FieldMedicine
TopicRenal Transplantation Outcomes and Treatments
Canadian institutionsUniversity of SaskatchewanMemorial University of Newfoundland
Fundersnot available
KeywordsRenal functionCirrhosisAscitesPlasma clearanceUrologyExtrapolationSampling (signal processing)ChemistryInternal medicineMathematicsMedicinePharmacokineticsStatisticsPhysics

Abstract

fetched live from OpenAlex

AIM: The aim of this study was to identify a practical sampling regimen and calculation method that could be used to measure the glomerular filtration rate in patients with ascites using plasma sampling. PATIENTS AND METHODS: Thirteen potential liver transplant patients with cirrhosis and ascites were injected with Cr-51 ethylenediaminetetraacetic acid, and plasma samples were obtained at up to 16 time points for each patient. Reference clearance values were calculated using the area under the plasma clearance curve, which was calculated using all the available data points. Clearance calculations were then performed using three and four data points from each patient and three different calculation methods to identify a sampling regimen and calculation method that yielded good agreement with the reference values. RESULTS: The reference clearances ranged from 6 to 80 ml/min. Sampling at 2, 4, 8 and 24 h and calculation of the area under the plasma clearance curve using a log-linear trapezoidal rule with extrapolation to zero and infinity yielded a relative root mean square difference from the reference of less than 7%. CONCLUSION: This method for measuring glomerular filtration rate in patients with cirrhosis and ascites was found to be more accurate than the slope-intercept technique and is a practical alternative to urine collection.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.004
Threshold uncertainty score0.023

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.012
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.347
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueNuclear Medicine CommunicationsSame topicRenal Transplantation Outcomes and TreatmentsFrench-language works237,207