MétaCan
Menu
Back to cohort
Record W2322124307 · doi:10.1117/12.2216094

Current sensing for navigated electrosurgery: proof of concept

2016· article· en· W2322124307 on OpenAlexaff
K. Carter, András Lassó, Tamás Ungi, Evelyn Morin, Gábor Fichtinger

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2016
Typearticle
Languageen
FieldMedicine
TopicThyroid and Parathyroid Surgery
Canadian institutionsQueen's University
Fundersnot available
KeywordsComputer scienceMicrocontrollerProof of conceptCurrent (fluid)Power (physics)ElectrosurgeryComparatorElectrical engineeringReal-time computingVoltageComputer hardwarePhysics

Abstract

fetched live from OpenAlex

PURPOSE: Tracked power-tools are routinely used in computer-assisted intervention and surgical systems. In order to properly perform temporal and spatial monitoring of the tracked tool with the navigation system, it is important to know when the tool, such as an electrosurgical cauterizer, is being activated during surgery. We have developed a general purpose current sensor that can be augmented to tracked surgical devices in order to inform the surgeon and the navigation system when the tool is activated. METHODS: Two non-invasive AC current sensors, two peak detector circuits, one voltage comparator circuit, and a microcontroller were used to detect when an electrosurgical cauterizer is being powered on and differentiate between the cut and coagulation modes. The system was tested by cauterizing various substances at varied power ratings. RESULTS: By comparing the ratio of amplitudes as well as the frequencies of the signals, the current sensing system is able to differentiate between on/off, cut/coagulation, as well as when cauterizer tissue. DISCUSSION: The current sensing system is able to detect when the cauterizer is being powered on and can differentiate between monopolar cut and coagulation modes. CONCLUSION: This system shows promise for detecting when the cauterizer is being powered on and in the future could be integrated with a navigation system in order to easily temporally monitor the electrosurgical tool.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.254
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicThyroid and Parathyroid SurgeryFrench-language works237,207