MétaCan
Menu
Back to cohort
Record W2323950504 · doi:10.1177/0885328211433778

PDMS embedded microneedles as a controlled release system for the eye

2012· article· en· W2323950504 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueJournal of Biomaterials Applications · 2012
Typearticle
Languageen
FieldPharmacology, Toxicology and Pharmaceutics
TopicAdvancements in Transdermal Drug Delivery
Canadian institutionsMcMaster University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsMaterials scienceBiomedical engineeringScleraMicrochannelEx vivoDrug deliveryIn vivoNanotechnologySurgery

Abstract

fetched live from OpenAlex

PURPOSE: To demonstrate intraocular drug delivery using a novel device fabricated by embedding hollow glass microneedles within a soft and flexible poly (dimethylsiloxane) (PDMS) substrate for ease of device insertion into the eye. METHODS: Hollow glass microneedles (5 µm ID tips), fabricated using standard glass drawing techniques, were assembled into a photolithographically micropatterned PDMS substrate. The microneedles were fluidically coupled to a drug reservoir through a 300 µm microchannel to test for in vitro release of 6-aminoquinolone (144 Da) and Rose Bengal (1044 Da). Intravitreal delivery in ex vivo bovine eyes was also studied. RESULTS: The microneedles penetrated UV-crosslinked collagen and excised bovine sclera without breaking or delaminating from the PDMS matrix. A total of 45 ng of 6-aminoquinolone and 16 µg of Rose Bengal was released into buffered saline over a 20-min infusion at a delivery rate of 50 µL/min. Microinjection of Rose Bengal for 8 h into ex vivo bovine vitreous resulted in a total mass accumulation of 0.0202 mg into both phases of the vitreous humor and to the uveal face of the sclera without clogging of the internal needle microchannel. CONCLUSIONS: PDMS-embedded microneedles offer an integrated method of drug targeting to the intraocular tissues using a less invasive and less painful approach when compared with macroscale hypodermic needles. The release rates from the microneedles were controllable on demand using a syringe pump and were independent of the properties of the drugs tested. The device demonstrated a new hybrid approach of coupling rigid microneedles strong enough to penetrate the tough, fibrous sclera with a soft and pliable PDMS substrate that could conform to the contours of the eye.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.410
Threshold uncertainty score0.436

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.074
GPT teacher head0.447
Teacher spread0.373 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it