MétaCan
Menu
Back to cohort
Record W2324829802 · doi:10.3928/01477447-20110505-12

Fracture Load for Periprosthetic Femoral Fractures in Cemented Versus Uncemented Hip Stems: An Experimental In Vitro Study

2008· article· en· W2324829802 on OpenAlexaboutno aff
M. Thomsen, Eike Jakubowitz, Joern B. Seeger, Christoph I. Lee, Jan Philippe Kretzer, Michael Clarius

Bibliographic record

VenueOrthopedics · 2008
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsPeriprostheticMedicineFemurCadaveric spasmFemoral fractureDentistryFracture (geology)Hip fractureOrthopedic surgerySurgeryWeight-bearingArthroplastyOrthodonticsOsteoporosisGeotechnical engineeringInternal medicineGeology

Abstract

fetched live from OpenAlex

This cadaveric study examined fracture loads in cemented and uncemented hip stems. Additionally, individual data and bone quality were analyzed and correlated to fracture patterns and fracture load. Cemented or uncemented hip stems were implanted in a randomized fashion in 10 matched paired fresh-frozen femora (donor median age, 78 years, and donor median weight, 74.2 kg). Bone density was measured before the femurs were fractured under load (maximum load of 10,000 N), and fracture patterns were analyzed according to the Vancouver and Johansson classification systems. In the uncemented group, all of the femurs fractured with a median load of 2625 N (range, 1725-7647 N). In the cemented group, 5 femurs fractured with a median maximum load of 9127 N (range, 2845-10,000 N) and 5 femurs did not fracture with a maximum load of 10,000 N. Fracture load corresponded to 4 times and 8.8 times body weight in the uncemented and cemented groups, respectively. Fracture patterns corresponded to Vancouver type A fractures in uncemented stems and Vancouver type C fractures in cemented hip stems. Analysis showed a significant correlation between fracture load and bone density in the uncemented group, whereas there was no correlation in the cemented group. Patients with poor bone quality treated with an uncemented hip stem are at higher risk for periprosthetic fractures; therefore, we recommend cemented stems in this group of patients. Cementation appears to protect against periprosthetic fractures, probably from internal stiffening of the femoral cavity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.337
Teacher spread0.290 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations44
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueOrthopedicsSame topicOrthopaedic implants and arthroplastyFrench-language works237,207