Restoration and Spectral Recovery of Mid-Infrared Chemical Images
Bibliographic record
Abstract
Fourier transform infrared (FTIR) microspectroscopy is a powerful technique for label-free chemical imaging that has supplied important chemical information about heterogeneous samples for many problems across a variety of disciplines. State-of-the-art synchrotron based infrared (IR) microspectrometers can yield high-resolution images, but are truly diffraction limited for only a small spectral range. Furthermore, a fundamental trade-off exists between the number of pixels, acquisition time and the signal-to-noise ratio, limiting the applicability of the technique. The recently commissioned infrared synchrotron beamline, infrared environmental imaging (IRENI), overcomes this trade off and delivers 4096-pixel diffraction limited IR images with high signal-to-noise ratio in under a minute. The spatial oversampling for all mid-IR wavelengths makes the IRENI data ideal for spatial image restoration techniques. Here, we measured and fitted wavelength-dependent point-spread-functions (PSFs) at IRENI for a 74× objective between the sample plane and detector. Noise-free wavelength-dependent theoretical PSFs are deconvoluted from images generated from narrow bandwidths (4 cm(-1)) over the entire mid-infrared range (4000-900 cm(-1)). The stack of restored images is used to reconstruct the spectra. Restored images of metallic test samples with features that are 2.5 μm and smaller are clearly improved in comparison to the raw data images for frequencies above 2000 cm(-1). Importantly, these spatial image restoration methods also work for samples with vibrational bands in the recorded mid-IR fingerprint region (900-1800 cm(-1)). Improved signal-to-noise spectra are reconstructed from the restored images as demonstrated for a mixture of spherical polystyrene beads in a polyurethane matrix. Finally, a freshly thawed retina tissue section is used to demonstrate the success of deconvolution achievable with a heterogeneous, irregularly shaped, biologically relevant sample with distinguishing spectroscopic features across the entire mid-IR spectral range.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".