Aging Effects on Detection of Spectral Changes Induced by a Break in Sound Correlation
Bibliographic record
Abstract
In Brief Objectives: Previous studies have shown that both younger adults and older adults with clinically normal hearing are able to detect a break in correlation (BIC) between interaurally correlated sounds presented over headphones. This ability to detect a BIC improved when the correlated sounds were presented over left and right loudspeakers rather than over left and right headphones, suggesting that additional spectral cues provided by comb filtering (caused by interference between the two channels) facilitate detection of the BIC. However, older adults receive significantly less benefit than younger adults from a switch to loudspeaker presentation. It is hypothesized that this is a result of an age-related reduction in the sensitivity to the monaural spectral cues provided by comb filtering. Design: Two experiments were conducted in this study. Correlated white noises with a BIC in the temporal middle were presented from two spatially separated loudspeakers (positioned at ±45-degree azimuth) and recorded at the right ear of a Knowles Electronic Manikin for Acoustic Research (KEMAR). In Experiment 1, the waveforms recorded at the KEMAR’s right ear were presented to the participant’s right ear over a headphone in 14 younger adults and 24 older adults with clinically normal hearing. In Experiment 2, 8 of the 14 younger participants participated. Under the monaurally cueing condition, the waveforms recorded at the KEMAR’s right ear were presented to the participant’s right ear as Experiment 1. Under the binaurally cueing condition, waveforms delivered from the left loudspeaker and those from the right loudspeaker were recorded at the KEMAR’s left and right ear, respectively, thereby eliminating the spectral ripple cue, and were presented to the participant’s left and right ears, respectively. For each of the two experiments, the break duration threshold for detecting the BIC was examined when the interloudspeaker interval (delay) (ILI) was 0, 1, 2, or 4 msec (left loudspeaker leading). Results: In Experiment 1, both younger participants and older participants detected the BIC in the waveforms recorded by the right ear of KEMAR, but older participants had higher detection thresholds than younger participants when the ILI was 0, 2, or 4 msec without an effect of SPL shift between 59 and 71 dB. In Experiment 2, each of the eight younger participants was able to detect the occurrence of the BIC in either the monaurally cueing or binaural-cueing condition. In addition, the detection threshold under the monaurally cueing condition was substantially the same as that under the binaurally cueing condition at each of the four ILIs. Conclusions: Younger adults and older adults with clinically normal hearing are able to detect the monaural spectral changes arising from comb filtering when a sudden drop in intersound correlation is introduced. However, younger adults are more sensitive than older adults are, at detecting the BIC. The findings suggest that older adults are less able than younger adults to detect a periodic ripple in the sound spectrum. This age-related ability reduction may contribute to older adults’ difficulties in hearing under noisy, reverberant conditions. Detecting a transient break in correlation between correlated sounds is much easier when presented over two loudspeakers than when presented over two headphones. However, older adults benefit less than did younger adults from a change from headphone to loudspeaker presentation (see Ear Hear, 30, 273-286), suggesting an age-related reduction in sensitivity to monaural or binaural spectral cues provided by comb filtering. In this study, the monaural spectral cues present in the sound field were isolated and extracted, and then presented over headphones to younger adults and older adults with clinically normal hearing. Compared with younger adults, older adults exhibited a reduced sensitivity to the monaural spectral cues, particularly when an interloudspeaker time interval was introduced.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".