MétaCan
Menu
Back to cohort
Record W2331891130 · doi:10.1097/ccm.0000000000001486

Sympathetic Vasoconstrictor Responsiveness of the Leg Vasculature During Experimental Endotoxemia and Hypoxia in Humans

2015· article· en· W2331891130 on OpenAlexaff
Patrice Brassard, Morten Zaar, Pia Thaning, Niels H. Secher, Jaya Birgitte Rosenmeier

Bibliographic record

VenueCritical Care Medicine · 2015
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsInstitut universitaire de cardiologie et de pneumologie de Québec
Fundersnot available
KeywordsMedicineHypoxia (environmental)Vasoconstrictor AgentsCardiologyAnesthesiaVasodilationOxygen

Abstract

fetched live from OpenAlex

OBJECTIVE: Sympathetic vasoconstriction regulates peripheral circulation and controls blood pressure, but sepsis is associated with hypotension. We evaluated whether apparent loss of sympathetic vasoconstrictor responsiveness relates to distended smooth muscles or to endotoxemia and/or hypoxia. DESIGN: Prospective descriptive study. SETTING: Hospital research laboratory. SUBJECTS: Ten healthy young men (age [mean ± SD], 31 ± 8 yr; body weight, 83 ± 10 kg) participated in the study. INTERVENTIONS: Leg blood flow and mean arterial pressure were determined, whereas leg vascular conductance was calculated during 1) adenosine infusion (vasodilator control), 2) hypoxia (FIO2 = 10%), 3) endotoxemia, and 4) endotoxemia + hypoxia. Leg sympathetic vasoconstrictor responsiveness (reduction in leg vascular conductance) was evaluated by femoral artery tyramine infusion. MEASUREMENTS AND MAIN RESULTS: Endotoxemia increased body temperature from 36.9 ± 0.4°C to 38.6 ± 0.5°C (p < 0.01) and plasma tumor necrosis factor-α from 6 pg/mL (3-8 pg/mL) to 391 pg/mL (128-2258 pg/mL) (p < 0.01; median [range]). Mean arterial pressure decreased similarly during endotoxemia (-11% ± 16%) and endotoxemia + hypoxia (-10% ± 15%; both p < 0.05). Leg blood flow and leg vascular conductance were not affected by endotoxemia, whereas both were elevated by adenosine infusion (leg blood flow, +94% ± 61%; leg vascular conductance, +97% ± 57%), hypoxia (leg blood flow: +93% ± 58%; leg vascular conductance, +100% ± 115%), and endotoxemia + hypoxia (leg blood flow, +67% ± 120%; leg vascular conductance, +65% ± 57%; p < 0.05). Endotoxemia lessened the tyramine-induced reduction in leg vascular conductance (-28% ± 13%) compared with the reduction during adenosine infusion (-47% ± 5%; p < 0.05). Also, endotoxemia + hypoxia (-17% ± 21%) attenuated the tyramine-induced reduction in leg vascular conductance compared with both adenosine infusion and hypoxia (-45% ± 13%; p < 0.05). CONCLUSIONS: Both endotoxemia and combined hypoxia and endotoxemia blunted sympathetic vasoconstrictor responsiveness. Furthermore, tyramine normalized the doubled leg vascular conductance during administration of adenosine, suggesting that distension of vascular smooth muscles does not explain blunted sympathetic vasoconstrictor responsiveness during endotoxemia.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.325
Teacher spread0.301 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueCritical Care MedicineSame topicHemodynamic Monitoring and TherapyFrench-language works237,207