MétaCan
Menu
Back to cohort
Record W2332209151 · doi:10.1021/ac401424j

Fluorous Membrane Ion-Selective Electrodes for Perfluorinated Surfactants: Trace-Level Detection and in Situ Monitoring of Adsorption

2013· article· en· W2332209151 on OpenAlexaboutno aff
Li D. Chen, Chun‐Ze Lai, Laura P. Granda, Melissa A. Fierke, Debaprasad Mandal, Andreas Stein, John A. Gladysz, Philippe Bühlmann

Bibliographic record

VenueAnalytical Chemistry · 2013
Typearticle
Languageen
FieldChemical Engineering
TopicAnalytical Chemistry and Sensors
Canadian institutionsnot available
FundersMaterials Research Science and Engineering Center, Harvard UniversityUniversity of PennsylvaniaU.S. Environmental Protection AgencyNational Science Foundation
KeywordsChemistryDetection limitChromatographyPotentiometric titrationAdsorptionAnalyteMass spectrometryMembraneIon exchangeAmmoniumSelectivityIn situAnalytical Chemistry (journal)IonOrganic chemistry

Abstract

fetched live from OpenAlex

Ion-selective electrodes (ISEs) with fluorous anion-exchanger membranes for the potentiometric detection of perfluorooctanoate (PFO(-)) and perfluorooctanesulfonate (PFOS(-)) were developed. Use of an anion-exchanger membrane doped with the tetraalkylphosphonium derivative (Rf8(CH2)2)(Rf6(CH2)2)3P(+) and an optimized measurement protocol resulted in detection limits of 2.3 × 10(-9) M (1.0 ppb) for PFO(-) and 8.6 × 10(-10) M (0.43 ppb) for PFOS(-). With their higher selectivity for PFO(-) over OH(-), membranes containing the alternative anion exchanger (Rf6(CH2)3)3PN(+)P((CH2)3Rf6)3 with a bis(phosphoranylidene)ammonium group further improved the detection limit for PFO(-) to 1.7 × 10(-10) M (0.070 ppb). These values are comparable with results obtained using well-established techniques such as gas chromatography-mass spectrometry (GC-MS), liquid chromatography-mass spectrometry (LC-MS), and liquid chromatography-tandem mass spectrometry (LC-MS-MS), but the measurement with ISEs avoids lengthy sample preconcentration, can be performed in situ, and is less costly. Even when eventual spectrometric confirmation of analyte identity is required, prescreening of large numbers of samples or in situ monitoring with ISEs may be of substantial benefit. To demonstrate a real-life application of these electrodes, in situ measurements were performed of the adsorption of PFOS(-) onto Ottawa sand, which is a standard sample often used in environmental sciences. The results obtained are consistent with those from an earlier LC-MS study, validating the usefulness of these sensors for environmental studies. Moreover, PFOS(-) was successfully measured in a background of water from Carnegie Lake.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0030.001
Insufficient payload (model declined to judge)0.0000.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.240
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations81
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicAnalytical Chemistry and SensorsFrench-language works237,207