Iterative Reconstruction for Head CT: Effects on Radiation Dose and Image Quality

2014· article· en· W2333121238 on OpenAlexaffvenue
Michael D. Rivers-Bowerman, Jai Shankar

Bibliographic record

VenueCanadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · 2014
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsQueen Elizabeth II Health Sciences CentreDalhousie UniversitySaint Mary's University
Fundersnot available
KeywordsImage qualityNuclear medicineIterative reconstructionWilcoxon signed-rank testRadon transformMedicineRadiation doseMathematicsRadiologyComputer scienceArtificial intelligenceImage (mathematics)Mann–Whitney U test

Abstract

fetched live from OpenAlex

BACKGROUND: Iterative reconstruction has been reported to reduce radiation dose in CT, while preserving and even improving image quality. The purpose of this study was to evaluate the effects of sinogram-affirmed iterative reconstruction (SAFIRE) on radiation dose reduction and image quality for noncontrast adult head CT and to compare SAFIRE with conventional filtered back-projection (FBP) reconstruction. METHODS: Institutional review board approval was obtained for this retrospective analysis of head CT scans reconstructed with SAFIRE and/or FBP for 107 patients. Radiation dose parameters were recorded from scanner-generated CT dose reports. Signal-to-noise and contrast-to-noise ratios (SNR, CNR) were calculated from gray and white matter (GM, WM) attenuation measurements. Image noise, artifacts, GM-WM differentiation, small structure visibility, and sharpness were graded by two readers. Statistical analysis included the independent-samples t test for quantitative data, the related samples Wilcoxon signed-rank test for qualitative data, the coefficient of repeatability for intraobserver variation, and κ statistics for interobserver agreement. RESULTS: Mean effective dose was significantly reduced with SAFIRE from 2.0 to 1.7 mSv (p<0.0001). SAFIRE also significantly improved GM SNR, WM SNR, and GM-WM CNR (p<0.0001). Significant reductions in image noise and posterior fossa artifact as well as improvements in GM-WM differentiation, small structure visibility, and sharpness were noted with SAFIRE (P<0.005). CONCLUSIONS: SAFIRE for noncontrast adult head CT reduces patient radiation dose by 15% for the settings employed at our institution, while significantly improving multiple quantitative and qualitative measures of image quality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.006
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesScience and technology studies
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.255
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0020.002
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.323
Teacher spread0.289 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Journal of Neurological Sciences / Journal Canadien des Sciences NeurologiquesSame topicRadiation Dose and ImagingFrench-language works237,207