MétaCan
Menu
Back to cohort
Record W2333500897 · doi:10.4244/eijy14m11_02

Five-year outcomes from a trial of three limus-eluting stents with different polymer coatings in patients with coronary artery disease: final results from the ISAR-TEST 4 randomised trial

2016· article· en· W2333500897 on OpenAlex
Sebastian Kufner, Robert A. Byrne, Marco Valeskini, S. Schulz, Tareq Ibrahim, Petra Hoppmann, Simon Schneider, Karl‐Ludwig Laugwitz, Heribert Schunkert, Adnan Kastrati

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueEuroIntervention · 2016
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineSirolimusClinical endpointStentMyocardial infarctionTarget lesionEverolimusInternal medicineSurgeryCoronary artery diseaseCardiologyUrologyRandomized controlled trialPercutaneous coronary intervention

Abstract

fetched live from OpenAlex

AIMS: Both biodegradable polymer sirolimus-eluting stents and permanent polymer everolimus-eluting stents offer potential for enhanced late outcomes in comparison with earlier-generation permanent polymer sirolimus-eluting stents. However, long-term comparative efficacy data among these devices remain a scientific gap. We aimed to compare the efficacy and safety of biodegradable polymer sirolimus-eluting stents (Yukon Choice PC) versus permanent polymer everolimus-eluting stents (XIENCE) versus permanent polymer sirolimus-eluting stents (CYPHER) at five-year follow-up. METHODS AND RESULTS: Overall, 2,603 patients were randomised to treatment with the Yukon Choice PC (n=1,299), XIENCE (n=652) or CYPHER (n=652) stents. The primary endpoint was the device-oriented composite of cardiac death, target vessel-related myocardial infarction (MI), or target lesion revascularisation (TLR). The main secondary endpoint was definite/probable stent thrombosis (ST). Follow-up was performed up to five years. Concerning the primary endpoint, there was no significant difference between Yukon Choice PC and XIENCE stents (20.5% vs. 19.5%, HR=1.04, 95% CI: 0.84-1.29; p=0.71) or between CYPHER and XIENCE stents (23.5% vs. 19.5%, HR=1.21, 95% CI: 0.95-1.53; p=0.12). In terms of safety, rates of ST were similar with both Yukon Choice PC and XIENCE (1.2% vs. 1.4%; HR=0.83, 95% CI: 0.37-1.91; p=0.67) but numerically higher with CYPHER as compared to XIENCE (2.4% vs. 1.4%, HR=1.67, 95% CI: 0.73-3.82; p=0.22). CONCLUSIONS: Biodegradable polymer Yukon Choice PC and permanent polymer XIENCE stents showed comparable clinical outcomes at five years. Permanent polymer CYPHER stents showed numerically higher rates of device-related adverse events. Trials registration: ClinicalTrials.gov (identifier: NCT00598676).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.045
Threshold uncertainty score0.552

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.258
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it