MétaCan
Menu
Back to cohort
Record W2333500897 · doi:10.4244/eijy14m11_02

Five-year outcomes from a trial of three limus-eluting stents with different polymer coatings in patients with coronary artery disease: final results from the ISAR-TEST 4 randomised trial

2016· article· en· W2333500897 on OpenAlexaboutno aff
Sebastian Kufner, Robert A. Byrne, Marco Valeskini, S. Schulz, Tareq Ibrahim, Petra Hoppmann, Simon Schneider, Karl‐Ludwig Laugwitz, Heribert Schunkert, Adnan Kastrati

Bibliographic record

VenueEuroIntervention · 2016
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineSirolimusClinical endpointStentMyocardial infarctionTarget lesionEverolimusInternal medicineSurgeryCoronary artery diseaseCardiologyUrologyRandomized controlled trialPercutaneous coronary intervention

Abstract

fetched live from OpenAlex

AIMS: Both biodegradable polymer sirolimus-eluting stents and permanent polymer everolimus-eluting stents offer potential for enhanced late outcomes in comparison with earlier-generation permanent polymer sirolimus-eluting stents. However, long-term comparative efficacy data among these devices remain a scientific gap. We aimed to compare the efficacy and safety of biodegradable polymer sirolimus-eluting stents (Yukon Choice PC) versus permanent polymer everolimus-eluting stents (XIENCE) versus permanent polymer sirolimus-eluting stents (CYPHER) at five-year follow-up. METHODS AND RESULTS: Overall, 2,603 patients were randomised to treatment with the Yukon Choice PC (n=1,299), XIENCE (n=652) or CYPHER (n=652) stents. The primary endpoint was the device-oriented composite of cardiac death, target vessel-related myocardial infarction (MI), or target lesion revascularisation (TLR). The main secondary endpoint was definite/probable stent thrombosis (ST). Follow-up was performed up to five years. Concerning the primary endpoint, there was no significant difference between Yukon Choice PC and XIENCE stents (20.5% vs. 19.5%, HR=1.04, 95% CI: 0.84-1.29; p=0.71) or between CYPHER and XIENCE stents (23.5% vs. 19.5%, HR=1.21, 95% CI: 0.95-1.53; p=0.12). In terms of safety, rates of ST were similar with both Yukon Choice PC and XIENCE (1.2% vs. 1.4%; HR=0.83, 95% CI: 0.37-1.91; p=0.67) but numerically higher with CYPHER as compared to XIENCE (2.4% vs. 1.4%, HR=1.67, 95% CI: 0.73-3.82; p=0.22). CONCLUSIONS: Biodegradable polymer Yukon Choice PC and permanent polymer XIENCE stents showed comparable clinical outcomes at five years. Permanent polymer CYPHER stents showed numerically higher rates of device-related adverse events. Trials registration: ClinicalTrials.gov (identifier: NCT00598676).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.026

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.005
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0040.005
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0020.003
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.258
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations64
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueEuroInterventionSame topicCoronary Interventions and DiagnosticsFrench-language works237,207