MétaCan
Menu
Back to cohort
Record W2334267880 · doi:10.1021/ac5010579

Measurement of a Doubly Substituted Methane Isotopologue, <sup>13</sup>CH<sub>3</sub>D, by Tunable Infrared Laser Direct Absorption Spectroscopy

2014· article· en· W2334267880 on OpenAlexafffund
Shuhei Ono, David T. Wang, Danielle S. Gruen, Barbara Sherwood Lollar, M. S. Zahniser, J. Barry McManus, David D. Nelson

Bibliographic record

VenueAnalytical Chemistry · 2014
Typearticle
Languageen
FieldEnvironmental Science
TopicAtmospheric and Environmental Gas Dynamics
Canadian institutionsUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of CanadaU.S. Department of EnergyNational Science Foundation
KeywordsIsotopologueChemistryAbsorption (acoustics)InfraredSpectroscopyInfrared spectroscopyAnalytical Chemistry (journal)Absorption spectroscopyMethaneLaserParts-per notationOpticsMoleculeEnvironmental chemistry

Abstract

fetched live from OpenAlex

Methane is an important energy resource and significant long-lived greenhouse gas. Carbon and hydrogen isotope ratios have been used to better constrain the sources of methane but interpretations based on these two parameters alone can often be inconclusive. The precise measurement of a doubly substituted methane isotopologue, (13)CH3D, is expected to add a critical new dimension to source signatures by providing the apparent temperature at which methane was formed or thermally equilibrated. We have developed a new method to precisely determine the relative abundance of (13)CH3D by using tunable infrared laser direct absorption spectroscopy (TILDAS). The TILDAS instrument houses two continuous wave quantum cascade lasers; one tuned at 8.6 μm to measure (13)CH3D, (12)CH3D, and (12)CH4, and the other at 7.5 μm to measure (13)CH4. With the use of an astigmatic Herriott cell with an effective path length of 76 m, a precision of 0.2‰ (2σ) was achieved for the measurement of (13)CH3D abundance in ca. 10 mL STP (i.e., 0.42 mmol) pure methane samples. Smaller quantity samples (ca. 0.5 mL STP) can be measured at lower precision. The accuracy of the Δ(13)CH3D measurement is 0.7‰ (2σ), evaluated by thermally equilibrating methane with a range of δD values. The precision of ±0.2‰ corresponds to uncertainties of ±7 °C at 25 °C and ±20 °C at 200 °C for estimates of apparent equilibrium temperatures. The TILDAS instrument offers a simple and precise method to determine (13)CH3D in natural methane samples to distinguish geological and biological sources of methane in the atmosphere, hydrosphere, and lithosphere.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.037
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.200
Teacher spread0.193 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations152
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicAtmospheric and Environmental Gas DynamicsFrench-language works237,207