MétaCan
Menu
Back to cohort
Record W2334373805 · doi:10.1097/rli.0b013e3181fac6ef

Whole-Heart Coronary Magnetic Resonance Angiography at 1.5 Tesla

2010· article· en· W2334373805 on OpenAlexaff
Moritz Wagner, Roberta Rösler, Alexander Lembcke, Craig Butler, Marc Dewey, Michael Laule, Alexander Huppertz, Carsten Schwenke, Carsten Warmuth, Matthias Rief, Bernd Hamm, Matthias Taupitz

Bibliographic record

VenueInvestigative Radiology · 2010
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsMedicineConfidence intervalMagnetic resonance angiographyNuclear medicineMagnetic resonance imagingRadiologyInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVES: To evaluate the impact of the blood-pool contrast agent gadofosveset trisodium on diagnostic accuracy of whole-heart coronary magnetic resonance angiography (CMRA) at 1.5 Tesla. MATERIALS AND METHODS: Thirty consecutive patients with suspected coronary artery disease underwent free-breathing whole-heart CMRA at 1.5 Tesla. CMRA was performed with a T2-prepared steady-state free precession sequence (unenhanced CMRA) and an inversion-recovery-prepared steady-state free precession sequence after administration of gadofosveset trisodium (contrast-enhanced CMRA). Two readers independently performed a per-segment evaluation of CMRA (8 proximal and mid coronary segments) for detection of significant stenosis (≥50%) using invasive coronary angiography as reference. Disagreement was settled by consensus reading and interobserver variability was assessed using an unweighted kappa statistic. RESULTS: Whole-heart CMRA was successfully performed in 27 patients. The percentage of assessable segments was significantly lower on unenhanced CMRA compared with contrast-enhanced CMRA (Reader 1: 79% [170/216] vs. 89% [192/216], respectively; Reader 2: 73% [157/216] vs. 87% [188/216], respectively; P < 0.001). Intention-to-diagnose analysis of the consensus reading yielded sensitivity, specificity, and diagnostic accuracy of unenhanced versus contrast-enhanced CMRA as follows: 73.1% versus 73.1% (P = 1.0), 68.3% versus 80.2% (P = 0.002), and 68.9% versus 79.3% (P = 0.004), respectively. The kappa value for interobserver agreement was 0.61 (95% confidence interval = 0.50-0.72) for unenhanced CMRA and 0.72 (95% confidence interval = 0.62-0.82) for contrast-enhanced CMRA. CONCLUSIONS: The blood-pool contrast agent gadofosveset trisodium increased the number of assessable coronary segments on whole-heart CMRA in comparison to unenhanced whole-heart CMRA. The impact of gadofosveset trisodium on diagnostic accuracy, however, was only minor.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.770
Threshold uncertainty score0.647

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.002
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.287
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueInvestigative RadiologySame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207