MétaCan
Menu
Back to cohort
Record W2335243826 · doi:10.1097/bot.0000000000000009

The Effect of Radial Head Implant Length on Radiocapitellar Articular Properties and Load Transfer Within the Forearm

2013· article· en· W2335243826 on OpenAlexaff
Brent A. Lanting, Louis M. Ferreira, James A. Johnson, Graham J.W. King, George S. Athwal

Bibliographic record

VenueJournal of Orthopaedic Trauma · 2013
Typearticle
Languageen
FieldMedicine
TopicElbow and Forearm Trauma Treatment
Canadian institutionsWestern University
Fundersnot available
KeywordsForearmInterosseous membraneMedicineImplantCadaveric spasmElbowTension (geology)Head (geology)OrthodonticsRadial head fractureAnatomySurgeryRadial headMaterials scienceCompression (physics)Composite material

Abstract

fetched live from OpenAlex

BACKGROUND: The effect of radial head implant length on forearm biomechanics is not well understood. This study examined the influence of an increase or a decrease in radial head implant length on forearm load transfer as measured by interosseous membrane (IOM) tension and changes in radiocapitellar joint contact properties. METHODS: An upper extremity simulator was used to examine 6 cadaveric specimens with 5 different radial head implant lengths (-4 mm, -2 mm, anatomically correct, +2 mm, and +4 mm). A load-sensing device was woven into the fibers of IOM to quantify its tension. An interpositional pressure measurement sensor was used to determine radiocapitellar joint contact area and pressure. Axial loads of 160 N were applied to the forearm through active pronation and supination with the elbow fixed at 90 degrees of flexion. RESULTS: Increasing radial head implant length by 4 mm unloaded the IOM in all cases. Decreasing implant length by 4 mm significantly increased the IOM tension (P = 0.005). No significant differences were found in IOM tension between the correct head implant length and the -2 mm implant (P = 0.29). Contact pressure significantly increased with increasing radial head implant length (P = 0.021) and contact area diminished with both an increase and a decrease in radial head implant length, but this was not statistically significant (P = 0.051). CONCLUSIONS: Increasing radial head implant length decreased IOM tension and increased radiocapitellar joint contact pressure. CLINICAL RELEVANCE: These findings illustrate the importance of precise restoration of radial length when performing a radial head replacement. If the native radial head length is difficult to accurately assess, avoid increasing the length of the radial head to prevent detrimental changes in the biomechanics of the forearm and the potential for clinically important radiocapitellar joint pathology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.824
Threshold uncertainty score0.346

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.232
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Orthopaedic TraumaSame topicElbow and Forearm Trauma TreatmentFrench-language works237,207