MétaCan
Menu
Back to cohort
Record W2341098091 · doi:10.1177/0954411915621341

Hemodynamic study of the elliptic St. Jude Medical valve: A computational study

2016· article· en· W2341098091 on OpenAlexaff
Mehdi Jahandardoost, Guy Fradet, Hadi Mohammadi

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2016
Typearticle
Languageen
FieldEngineering
TopicLattice Boltzmann Simulation Studies
Canadian institutionsUniversity of British Columbia, Okanagan CampusUniversity of British Columbia
Fundersnot available
KeywordsHemodynamicsShear stressCardiologyMechanical heart-valveMechanical heartPressure dropHeart valveInternal medicineMaterials scienceStructural engineeringMedicineMechanicsEngineeringPhysicsComposite material

Abstract

fetched live from OpenAlex

Despite successful implantation of St. Jude Medical bileaflet mechanical heart valves, red blood cell lysis and thrombogenic complications associated with these types of valves are yet to be addressed. In our previous study, we proposed an elliptic housing where 10% ovality was applied to the housing of St. Jude Medical valves. Our preliminary results suggested that the overall hemodynamic performance of St. Jude Medical valves improved in both the closing and opening phases. In this study, we evaluated the hemodynamics around the leaflets in the opening phase using a more sophisticated computational platform, computational fluid dynamics. Results suggested both lower shear stress and wall shear stress values and an overall improved hemodynamic performance in the proposed design. This improvement is characterized by lower values of shear stress and wall shear stress in the regions downstream of the leaflets, lower pressure drop across the valve and smaller recirculation zones in the sinuses areas. The proposed design may open a new chapter in the concept of design and hemodynamic improvement of the next generation of mechanical heart valves.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.255
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicLattice Boltzmann Simulation StudiesFrench-language works237,207