Vascular refilling is independent of volume overload in hemodialysis with moderate ultrafiltration requirements

2016· article· en· W2342121145 on OpenAlexvenueno aff
Susanne Kron, Daniel Schneditz, Til Leimbach, Sabine Aign, Joachim Kron

Bibliographic record

VenueHemodialysis International · 2016
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsnot available
Fundersnot available
KeywordsHemodialysisBlood volumeDialysisVolume (thermodynamics)Ultrafiltration (renal)Intravascular volume statusVolume overloadMedicineBody waterHemodynamicsBody weightUrologyChemistryCardiologyInternal medicineSurgeryChromatographyThermodynamics

Abstract

fetched live from OpenAlex

Introduction Blood volume changes and vascular refilling during hemodialysis (HD) and ultrafiltration (UF) have been assumed to depend on volume overload (Vo ). It was the aim to study the magnitude of vascular refilling in stable HD patients with moderate volume expansion in everyday dialysis using novel technical approaches. Methods Patients were studied during routine dialysis and UF based on clinical dry weight assessment. Pre-dialysis Vo was independently measured by bioimpedance spectroscopy. Vascular refilling volume (Vref ) was calculated as: Vref = Vuf - ΔV, where ΔV is the absolute blood volume change determined by on-line dialysate dilution using a commercial on-line hemodiafiltration machine incorporating a relative blood volume monitor, and where Vuf is the prescribed UF volume. Findings Thirty patients (dry weight: 81.0 ± 17.8 kg) were studied. Pre-dialysis Vo was 2.46 ± 1.45 L. Vuf was 2.27 ± 0.71 L, specific UF rate was 6.45 ± 2.43 mL/kg/h, and since ΔV was 0.66 ± 0.31 L, Vref was determined as 1.61 ± 0.58 L, corresponding to a constant refilling fraction (Fref ) of 70.6 ± 10.6%. Vref strongly correlated with Vuf (r(2) = 0.82) but was independent of Vo and other volumes. Fref was also independent of Vo and other volumes normalized for various measures of body size. Discussion While vascular refilling and Fref is independent of Vo in treatments with moderate UF requirements, intravascular volume depletion increases with increasing UF requirements. The relationship between blood volume and Vo needs to be more closely examined in further studies to optimize volume control in everyday dialysis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.260
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicDialysis and Renal Disease ManagementFrench-language works237,207