MétaCan
Menu
Back to cohort
Record W2344655642

BIOMECHANICAL COMPARISON OF A UNIQUE PLATE VERSUS A STANDARD PLATE FOR INTERNAL FIXATION OF PROXIMAL HUMERUS FRACTURES IN A CADAVERIC MODEL

2008· article· en· W2344655642 on OpenAlexaboutno aff
Sarah A. Walsh, Rudolph Reindl, Edward J. Harvey, Greg Berry, Lorne Beckman, Thomas Steffen

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicShoulder and Clavicle Injuries
Canadian institutionsnot available
Fundersnot available
KeywordsCadaveric spasmInternal fixationHumerusProximal humerusMedicineRotator cuffFixation (population genetics)OrthodonticsSurgery
DOInot available

Abstract

fetched live from OpenAlex

Many two-part fractures of the proximal humerus are treated conservatively due to the frequent failure of internal fixation. The current investigation examines the biomechanical properties of a unique plate versus a standard plate for internal fixation of proximal humerus fractures. The unique plate employs screws that thread into the plate, creating a multi-planer, fixed angle device. A cadaveric model was developed that relied on the rotator cuff musculature as the primary deforming force. The locking plate displayed significantly greater holding power on the humeral head (p=0.007). This may lead to more consistent results in two-part fractures treated with internal fixation. The current investigation evaluates a unique plate designed to treat fractures of the proximal humerus. The plate employs screws that thread into the plate creating a fixed angle device. This plate was tested versus a standard cloverleaf plate. The locking plate displayed greater holding power on the humeral head in the model tested. This may lead to decreased failure rates in two-part fractures treated with internal fixation. Many two-part fractures of the proximal humerus are treated conservatively due to the frequent failure of common internal fixation modalities. This is done with the acceptance of possible non-union and loss of function. A more reliable method for stable internal fixation is therefore desirable. A significant difference was found (p=0.007) with the locking plate displaying greater holding capability on the humeral head. Eight pairs of preserved, cadaveric humeri were dissected and plated with either the locking plate or standard cloverleaf plate followed by an osteotomy at the surgical neck. A servo-hydraulic testing machine was then used to pull on the rotator cuff musculature until failure was achieved. Failure of the plate-head interface was reached in five of the eight pairs. Previous biomechanical studies have not taken into account the clinical mode of failure when testing internal fixation modalities for proximal humerus fractures. The current study has reproduced failure into varus by relying on the rotator cuff musculature as the primary deforming force. Funding: All implants donated by Synthes, Canada

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.056
GPT teacher head0.421
Teacher spread0.365 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2008
Admission routes1
Has abstractyes

Explore more

Same topicShoulder and Clavicle InjuriesFrench-language works237,207