MétaCan
Menu
Back to cohort
Record W2345565841 · doi:10.1177/0954411916642801

Wear simulation strategies for reverse shoulder arthroplasty implants

2016· article· en· W2345565841 on OpenAlexaff
G. Daniel G. Langohr, George S. Athwal, James A. Johnson, John B. Medley

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2016
Typearticle
Languageen
FieldMedicine
TopicShoulder Injury and Treatment
Canadian institutionsUniversity of WaterlooSt Joseph's Health Care
Fundersnot available
KeywordsArthroplastyProtocol (science)Cadaveric spasmImplantMedicineSimulationRange of motionComputer scienceSurgery

Abstract

fetched live from OpenAlex

Reverse total shoulder arthroplasty is a clinically accepted surgical procedure; however, its long-term wear performance is not known. The purpose of this work is to review wear simulator testing of reverse total shoulder arthroplasty, to develop a wear simulator protocol for reverse total shoulder arthroplasty, and to test it by performing a pilot study. The review of wear simulator testing in the literature revealed considerable variation in protocols. A combination of our own cadaveric testing and those of other research groups helped in determining the magnitude and direction of joint loading for the development of the present protocol. A MATCO orbital-bearing simulator was adapted using custom fixtures to simulate a circumduction motion of the shoulder under mildly adverse conditions, and a pilot study gave wear rates within the wide range found in the literature. Arguments were presented in support of the currently developed protocol, but it was also suggested that, rather than rely on one protocol, a series of simulator wear protocols should be developed to fully test the implant wear performance in reverse total shoulder arthroplasty.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.303
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicShoulder Injury and TreatmentFrench-language works237,207