MétaCan
Menu
Back to cohort
Record W2345706569 · doi:10.1167/iovs.15-18271

3D Corneal Shape After Implantation of a Biosynthetic Corneal Stromal Substitute

2016· article· en· W2345706569 on OpenAlexafffund
Jeb Alden Ong, Edouard Auvinet, Karolyn J. Forget, Neil Lagali, Per Fagerholm, May Griffith, Jean Meunier, Isabelle Brunette

Bibliographic record

VenueInvestigative Ophthalmology & Visual Science · 2016
Typearticle
Languageen
FieldMedicine
TopicCorneal surgery and disorders
Canadian institutionsUniversité de MontréalHôpital Maisonneuve-Rosemont
FundersCanadian Institutes of Health Research
KeywordsKeratoconusStromal cellCorneal transplantationMedicineImplantOphthalmologyCorneaCorneal TransplantSurgeryPathology

Abstract

fetched live from OpenAlex

PURPOSE: The current and projected shortage of transplantable human donor corneas has prompted the development of long-term alternatives to human donor tissue for corneal replacement. The biosynthetic stromal substitutes (BSS) characterized herein represent a potentially safe alternative to donor organ transplantation for anterior corneal stromal diseases. The goal of this phase 1 safety study was to characterize the three-dimensional (3D) corneal shape of the first 10 human patients implanted with a BSS and assess its stability over time. METHODS: Ten patients underwent anterior lamellar keratoplasty using a biosynthetic corneal stromal implant for either advanced keratoconus or central corneal scarring. Surgeries were performed at Linköping University Hospital, between October and November 2007. Serial corneal topographies were performed on all eyes up to a 4-year follow-up when possible. Three-dimensional shape average maps were constructed for the 10 BSS corneas and for 10 healthy controls. Average 3D shape corneal elevation maps, difference maps, and statistics maps were generated. RESULTS: The biosynthetic stromal substitutes implants remained stably integrated into the host corneas over the 4-year follow-up period, without signs of wound dehiscence or implant extrusion. The biosynthetic stromal substitutes corneas showed steeper surface curvatures and were more irregular than the healthy controls. CONCLUSIONS: Corneal astigmatism and surface steepness were observed 4 years after BSS implantation, while the implants remained stably integrated in the host corneas. Future studies will indicate if biomaterials technology will allow for the optimization of postoperative surface irregularity after anterior stromal replacement, a new window of opportunity that is not available with traditional corneal transplantation techniques.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesScience and technology studies
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.417
Threshold uncertainty score0.996

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.007
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.323
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueInvestigative Ophthalmology & Visual ScienceSame topicCorneal surgery and disordersFrench-language works237,207