MétaCan
Menu
Back to cohort
Record W2346007512 · doi:10.1055/s-0036-1583942

Differences between Manufacturers of Computed Tomography–Based Computer-Assisted Surgery Systems Do Exist

2016· review· en· W2346007512 on OpenAlexaff
Anas Nooh, Joushua Lubov, Ahmed Aoude, Sultan Aldebeyan, Peter Jarzem, Jean Ouellet, Michael H. Weber

Bibliographic record

VenueGlobal Spine Journal · 2016
Typereview
Languageen
FieldMedicine
TopicSpinal Fractures and Fixation Techniques
Canadian institutionsMcGill University Health Centre
Fundersnot available
KeywordsMedicineComputed tomographyRadiologySurgery

Abstract

fetched live from OpenAlex

STUDY DESIGN: Literature review. OBJECTIVE: Several studies have shown that the accuracy of pedicle screw placement significantly improves with use of computed tomography (CT)-based navigation systems. Yet, there has been no systematic review directly comparing accuracy of pedicle screw placement between different CT-based navigation systems. The objective of this study is to review the results presented in the literature and compare CT-based navigation systems relative only to screw placement accuracy. METHODS: Data sources included CENTRAL, Medline, PubMed, and Embase databases. Studies included were randomized clinical trials, case series, and case-control trials reporting the accuracy of pedicle screws placement using CT-based navigation. Two independent reviewers extracted the data from the selected studies that met our inclusion criteria. Publications were grouped based on the CT-based navigation system used for pedicle screw placement. RESULTS: < 0.0001, 95% confidence interval 0.92 to 1.23) in accuracy of pedicle screw placement between three different CT-based navigation systems. The mean (weighted) accuracy of pedicle screws placement based on the CT-based navigation system was found to be 97.20 ± 2.1% in StealthStation (Medtronic, United States) and 96.1 ± 3.9% in VectorVision (BrainLab, Germany). CONCLUSION: This review summarizes results presented in the literature and compares screw placement accuracy using different CT-based navigation systems. Although certain factors such as the extent of the procedure and the experience and skills of the surgeon were not accounted for, the differences in accuracy demonstrated should be considered by spine surgeons and should be validated for effects on patients' outcome.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.030
metaresearch head score (Gemma)0.171
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.030
Threshold uncertainty score0.159

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0300.171
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.006
Bibliometrics0.0170.024
Science and technology studies0.0010.002
Scholarly communication0.0040.004
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.061
GPT teacher head0.351
Teacher spread0.290 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueGlobal Spine JournalSame topicSpinal Fractures and Fixation TechniquesFrench-language works237,207