MétaCan
Menu
Back to cohort
Record W2346972206 · doi:10.1093/ehjci/jew025

Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging<sup>†</sup>

2016· review· en· W2346972206 on OpenAlexaff
Patrizio Lancellotti, Philippe Pîbarot, John B. Chambers, Thor Edvardsen, Victoria Delgado, Raluca Dulgheru, Mauro Pepi, Bernard Cosyns, Madalina Garbi, Julien Magné, Koen Nieman, Raphaël Rosenhek, Anne Bernard, Jorge Lowenstein, Marcelo Luiz Campos Vieira, Arnaldo Rabischoffsky, Rodrigo Hernández Vyhmeister, Xiao Zhou, Yun Zhang, J. L. Zamorano, Gilbert Habib

Bibliographic record

VenueEuropean Heart Journal - Cardiovascular Imaging · 2016
Typereview
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversité LavalInstitut universitaire de cardiologie et de pneumologie de Québec
FundersBritish Heart Foundation
KeywordsMedicineMagnetic resonance imagingRadiologyCardiac imagingClinical PracticeMedical imagingCardiologyNuclear imagingInternal medicineNuclear medicinePhysical therapy

Abstract

fetched live from OpenAlex

Prosthetic heart valve (PHV) dysfunction is rare but potentially life-threatening. Although often challenging, establishing the exact cause of PHV dysfunction is essential to determine the appropriate treatment strategy. In clinical practice, a comprehensive approach that integrates several parameters of valve morphology and function assessed with 2D/3D transthoracic and transoesophageal echocardiography is a key to appropriately detect and quantitate PHV dysfunction. Cinefluoroscopy, multidetector computed tomography, cardiac magnetic resonance imaging, and to a lesser extent, nuclear imaging are complementary tools for the diagnosis and management of PHV complications. The present document provides recommendations for the use of multimodality imaging in the assessment of PHVs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.008
Threshold uncertainty score0.037

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0070.012
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0020.003
Bibliometrics0.0080.005
Science and technology studies0.0010.001
Scholarly communication0.0020.003
Open science0.0040.002
Research integrity0.0040.005
Insufficient payload (model declined to judge)0.0060.007

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.329
Teacher spread0.312 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations539
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Heart Journal - Cardiovascular ImagingSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207