The instant results of transvenous catheter pulmonary vein cryoisolation for treating atrial fibrillation
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
Objective To investigate the instant effect of transvenous catheter pulmonary vein cryoisolation.Methods Twenty patients with atrial fibrillation,including 16 paroxysmal and 4 persistent atrial fibrillation,underwent pulmonary vein cryoisolation using an Arctic Circler catheter(CryoCath Technologies Inc.,Quebec,Canada).Results A total of 57 pulmonary veins were isolated and each vein was ablated for(5.64±2.57) times in average.Operation time was(265.88±52.20) min,and X-ray expoure time was(43.42±17.23) min.Two persistent atrial fibrillation stopped during the procedures,and the other 2 patients needed electroversion after ablation.The pulmonary vein potential recovered in 7(7/57,12.28%) pulmonary veins in 30 min.The further ablation was needed in these veins.Conclusion Transvenous catheter pulmonary vein cryoisolation for treatment of atrial fibrillation is effective instantly.The waiting time after isolation is needed for reducing recurrence.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it