MétaCan
Menu
Back to cohort
Record W2365249738

To analyze reasons of discarding as useless of α-Se direct conversion digital flat panel detector

2008· article· en· W2365249738 on OpenAlexaboutno aff
Na Yang

Bibliographic record

VenueChinese Medical Equipment Journal · 2008
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsnot available
Fundersnot available
KeywordsFlat panel detectorDetectorFlat panelMedical physicsComputer scienceNuclear medicineMedicineComputer graphics (images)Telecommunications
DOInot available

Abstract

fetched live from OpenAlex

Objective To analyze the reasons of discarding as useless of α-Se direct conversion digital flat panel detector (α-Se FPD). Methods (1) E-COM DR-2000CTM chest system, with high frequency X-ray machine made by CPI company of Canada, the X-ray tube made by VARIAN company of America and Direct Ray-1000 α-Se FPD made by DRC company of America. (2) 50 cases were collected rondomizedly, each had 4 pieces of chest image and were analyzed by two experienced radiologists and two technicians. Results After about 14 months with 30,000 times exposure efficacious, some damage lines and points appeared in the detector. After about 34 months with 70,000 times exposure efficacious, a damage region (area is 6.7in*0.95in ) existed, this reduced the images' quality and at the end the detector was discarded as useless. Conclusion The α-Se FPD needs maintenance and monitoring working circumstance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.267
Threshold uncertainty score0.593

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.257
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueChinese Medical Equipment JournalSame topicAdvanced X-ray and CT ImagingFrench-language works237,207