Depolarization Effect of Magneto-Optic Crystal GdYBiIG in Adjustable Magnetic Field
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
The optical system has been established in which the changes of polarization state for magneto optic crystal can be measured. In this optical system, WGY model semiconductor laser is applied as the light source, and the tuning range of the intensity of magnetic field is 0~1500 mT. Depolarization effect in GdYBiIG crystal which often be used in optical isolator is measured in large variation range of adjustable magnetic field. The experiment result shows that polarization performance will be best in GdYBiIG crystal when it reaches saturated magnetization. And the depolarization effect occurs when the intensity of magnetic field increases over saturation intensity. The principle for magnetic depolarization effect is also given according to the experimental result. It presents that magnetic circle dichroism and magnetic linear birefringence are the reasons which cause depolarization effect. From these results, it is optimum to make sure that the magnetic field should be lager only a little than the saturation intensity of magnetic field.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it