Elderly valve replacement with bioprostheses and mechanical prostheses. Comparison by composites of complications.
Bibliographic record
Abstract
AIM: The goal of aortic valve replacement (AVR) surgery in the elderly (= or >75 years) is to extend survival and minimize valve-related morbidity, mortality and reoperation. As the elderly population lives longer, those with implanted valves are at risk of suffering valve related complications. We hypothesize that bioprostheses are appropriate for the elderly. METHODS: The follow-up evaluation of 966 patients with valves (AVR, 666; mitral valve replacements [MVR], 226; multiple valve replacements [MR], 74) implanted between 1975 and 1999 was examined. There were 879 bioprotheses (BP) and 87 mechanical prostheses (MP). The mean age was 78.9+/-3.3 years (range 75-94.6 years). Concomitant coronary artery bypass was performed in AVR in 51.7%, MVR in 50.4% and MR in 28.4%. Valve type, valve lesion, coronary artery bypass (previous/concomitant), age and gender were considered as independent predictors of composites and survival. The total follow-up was 3905 patient-years. RESULTS: Early mortality was for AVR 9.6% (64), MVR 15.0% (34) and MR 25.7% (19). The late mortality was for AVR 8.8%, MVR 10.4% and MR 8.8%/patient-year. The only independent predictor of survival and valve-related mortality, morbidity and reoperation was age for survival in those with AVR, hazard ratio 1.15 [CL 1.03-1.27] p=0.0094). The BP reoperative rate was 0.5%/patient-year (reoperation was fatal in 6/15) of total, MP reoperative rate was 0% [reasons for reoperation structural valve deterioration (4), non-structural dysfunction (6), prosthetic valve endocarditis (5), reoperation fatality due to non-structural dysfunction (2), prosthetic valve endocarditis (4)]. Overall patient survival at 10 and 15 years, respectively, was 30.5+/-2.4% and 3.6+/-2.2% irrespective of valve position and type. Overall actual and actuarial freedom from valve-related morbidity at 15 years was 96.8+/-0.9% and 93.7+/-2.3%, respectively. Actual and actuarial overall freedom from valve-related mortality at 15 years was 84.3+/-2.4% and 58.4+/-0.9%, respectively. Overall actual and actuarial freedom from valve related reoperation at 15 years was 95.8+/-1.6% and 74.8+/-16.9%, respectively. CONCLUSIONS: BP valves are further confirmed to be a good option for AVR in patients = or >75 years of age.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.003 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.001 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".