Effects of acute volume loading and hemorrhage on intestinal vascular capacitance: a mechanism whereby capacitance modulates cardiac output.

2002· article· en· W2402235951 on OpenAlexaff
Nairne Scott‐Douglas, V.J. Robinson, Otto A. Smiseth, Christopher I. Wright, Dante E. Manyari, Eldon R. Smith, John V. Tyberg

Bibliographic record

VenuePubMed · 2002
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsUniversity of CalgaryFoothills Medical Centre
Fundersnot available
KeywordsCardiac outputMedicineBlood volumeCardiac function curveAnesthesiaCentral venous pressureStroke volumeVenous return curveConstrictionCardiologyVagovagal reflexSalineInternal medicineCardiac indexBlood pressureHemodynamicsReflexHeart rateHeart failure
DOInot available

Abstract

fetched live from OpenAlex

BACKGROUND: Changes in intestinal vascular capacitance during acute volume loading and hemorrhage have not been described. OBJECTIVES: To determine the effects of volume loading and hemorrhage on the intestinal vascular pressure-volume relationship and cardiac output. PATIENTS AND METHODS: In 11 alpha-chloralose-anesthetized dogs, a pneumatic portal venous constrictor and catheter were positioned to increase and measure portal venous pressure (Ppv), respectively. Relative changes in intestinal blood volume (IBV) were determined by blood-pool scintigraphy and expressed as the percentage change from control values (taken as 100%). Ppv-IBV relationships were constructed by graded portal vein constriction. RESULTS: IBV and cardiac output increased by 60 6% and 178 48%, respectively, and Ppv increased from 5.8 0.9 mmHg to 13.2 1.8 mmHg after initial volume loading (40 mL/kg of an isotonic glucose-saline solution over 7 min). IBV gradually decreased and reached near-control values after 75 min. In seven dogs, hemorrhage (sufficient to decrease mean aortic pressure by 56 4%) decreased IBV and cardiac output to 88 4% and 52 3% of control values, respectively, and Ppv decreased to 3.2 0.8 mmHg. CONCLUSIONS: A sigmoid function curve defined the relationship between cardiac output and IBV. Cardiac output remained constant over a wide range (between approximately 95% and 135% of control IBV). Outside this range, insufficient dilation or constriction resulted in a marked increase or decrease in venous pressures and cardiac output. These data indicate that vasculature capacitance modulates cardiac output during acute volume loading and hemorrhage, thereby maintaining cardiac output relatively constant over a wide range of total vascular blood volume.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.737
Threshold uncertainty score0.900

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.198
Teacher spread0.187 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2002
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicHemodynamic Monitoring and TherapyFrench-language works237,207