MétaCan
Menu
Back to cohort
Record W2406333822 · doi:10.1097/nnr.0000000000000111

A Novel Noninvasive Device to Assess Sympathetic Nervous System Function in Patients With Heart Failure

2015· article· en· W2406333822 on OpenAlexaffabout
Monica Parry, Chantelle A. Nielson, Fiona Muckle, Sheila O’Keefe-McCarthy, René van Lien, Jan H. Meijer

Bibliographic record

VenueNursing Research · 2015
Typearticle
Languageen
FieldMedicine
TopicHeart Rate Variability and Autonomic Control
Canadian institutionsKingston General HospitalSt. Lawrence CollegeRegistered Nurses' Association of Ontario
Fundersnot available
KeywordsImpedance cardiographyHeart failureMedicineCardiologyStroke volumeEjection fractionAmbulatoryHeart rateSympathetic nervous systemInternal medicineHemodynamicsBlood pressureCardiac function curveCardiac outputAnesthesiaPhysical therapy

Abstract

fetched live from OpenAlex

BACKGROUND: Heart failure is a complex syndrome associated with sympathetic nervous system and renin-angiotensin-aldosterone system hyperactivity. Sympathoinhibition and downregulation of sympathetic activity using medications and exercise training improve outcomes in patients with heart failure. Impedance cardiography provides data on hemodynamic and autonomic function that may assist with safe medication, exercise monitoring, and titration. PURPOSE: The purpose of this pilot study was to evaluate the sensitivity of the Vrije Universiteit Ambulatory Monitoring System (VU-AMS) version 5fs to detect hemodynamic and sympathetic nervous system changes associated with postural shift in persons with heart failure with reduced ejection fraction. METHODS: In this descriptive study, participants (N = 28) were recruited from an outpatient device clinic at a tertiary care hospital in Ontario, Canada. They completed a sit-to-stand posture protocol wearing an ambulatory blood pressure (ABP) and a noninvasive VU-AMS version 5fs impedance cardiography system. RESULTS: Most (n = 18, 64%) participants were eliminated from the final analyses in this sample because of difficulty in Q-onset and B-point identification in peculiar electrocardiogram and impedance cardiogram waveforms. The remaining participants (n = 10) had a mean age of 69 years (SD = 10 years) and responses to a sit-to-stand posture protocol that included a 5% increase in heart rate (p = .001), an 18% decrease in stroke volume (p = .01), and an 8% decrease in left ventricular ejection time (p = .01). Participants had an increased preejection period (11%, p = .01), a drop in cardiac output of 13% (p = .02), and a reduced mean arterial pressure of approximately 4% (p = .09) with standing. DISCUSSION: Although the VU-AMS version 5fs system detected anticipated hemodynamic and sympathetic nervous system changes to postural shift in participants (n = 10), the elimination of 64% (n = 18) of the sample because of scoring difficulties limits the use of this impedance cardiography device using standard scoring algorithms in persons with heart failure with reduced ejection fraction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.093
GPT teacher head0.359
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2015
Admission routes2
Has abstractyes

Explore more