MétaCan
Menu
Back to cohort
Record W2406333822 · doi:10.1097/nnr.0000000000000111

A Novel Noninvasive Device to Assess Sympathetic Nervous System Function in Patients With Heart Failure

2015· article· en· W2406333822 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueNursing Research · 2015
Typearticle
Languageen
FieldMedicine
TopicHeart Rate Variability and Autonomic Control
Canadian institutionsKingston General HospitalSt. Lawrence CollegeRegistered Nurses' Association of Ontario
Fundersnot available
KeywordsImpedance cardiographyHeart failureMedicineCardiologyStroke volumeEjection fractionAmbulatoryHeart rateSympathetic nervous systemInternal medicineHemodynamicsBlood pressureCardiac function curveCardiac outputAnesthesiaPhysical therapy

Abstract

fetched live from OpenAlex

BACKGROUND: Heart failure is a complex syndrome associated with sympathetic nervous system and renin-angiotensin-aldosterone system hyperactivity. Sympathoinhibition and downregulation of sympathetic activity using medications and exercise training improve outcomes in patients with heart failure. Impedance cardiography provides data on hemodynamic and autonomic function that may assist with safe medication, exercise monitoring, and titration. PURPOSE: The purpose of this pilot study was to evaluate the sensitivity of the Vrije Universiteit Ambulatory Monitoring System (VU-AMS) version 5fs to detect hemodynamic and sympathetic nervous system changes associated with postural shift in persons with heart failure with reduced ejection fraction. METHODS: In this descriptive study, participants (N = 28) were recruited from an outpatient device clinic at a tertiary care hospital in Ontario, Canada. They completed a sit-to-stand posture protocol wearing an ambulatory blood pressure (ABP) and a noninvasive VU-AMS version 5fs impedance cardiography system. RESULTS: Most (n = 18, 64%) participants were eliminated from the final analyses in this sample because of difficulty in Q-onset and B-point identification in peculiar electrocardiogram and impedance cardiogram waveforms. The remaining participants (n = 10) had a mean age of 69 years (SD = 10 years) and responses to a sit-to-stand posture protocol that included a 5% increase in heart rate (p = .001), an 18% decrease in stroke volume (p = .01), and an 8% decrease in left ventricular ejection time (p = .01). Participants had an increased preejection period (11%, p = .01), a drop in cardiac output of 13% (p = .02), and a reduced mean arterial pressure of approximately 4% (p = .09) with standing. DISCUSSION: Although the VU-AMS version 5fs system detected anticipated hemodynamic and sympathetic nervous system changes to postural shift in participants (n = 10), the elimination of 64% (n = 18) of the sample because of scoring difficulties limits the use of this impedance cardiography device using standard scoring algorithms in persons with heart failure with reduced ejection fraction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.123
Threshold uncertainty score0.423

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.093
GPT teacher head0.359
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it