MétaCan
Menu
Back to cohort
Record W2409219670 · doi:10.2174/1874325001610010155

Clinical and Biomechanical Evaluations of Staged Bilateral Total Knee Arthroplasty Patients with Two Different Implant Designs

2016· article· en· W2409219670 on OpenAlexaff
Alexandre Renaud, Alexandre Fuentes, Nicola Hagemeister, Martin Lavigne, Pascal‐André Vendittoli

Bibliographic record

VenueThe Open Orthopaedics Journal · 2016
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsÉcole de Technologie SupérieureUniversité de MontréalHôpital Maisonneuve-Rosemont
Fundersnot available
KeywordsMedicineAsymptomaticImplantWOMACGaitSagittal planeKinematicsOrthodonticsRadiographyRange of motionTotal knee arthroplastyBiomechanicsGait analysisKnee JointPhysical therapySurgeryOsteoarthritisPhysical medicine and rehabilitationRadiologyAnatomy

Abstract

fetched live from OpenAlex

BACKGROUND: Various implants of total knee arthroplasty (TKA) are used in clinical practice and each presents specific design characteristics. No implant managed this day to reproduce perfectly the biomechanics of the natural knee during gait. OBJECTIVES: We therefore asked whether (1) differences in tridimensional (3D) kinematic data during gait could be observed in two different designs of TKA on the same patients, (2) if those gait kinematic data are comparable with those of asymptomatic knees and (3) if difference in clinical subjective scores can be observed between the two TKA designs on the same patient. METHODS: We performed knee kinematic analysis on 15 patients (30 TKAs) with two different TKA implant designs (Nexgen, Zimmer and Triathlon, Stryker) on each knee and on 25 asymptomatic subjects (35 knees). Clinical evaluation included range of motion, weight bearing radiographs, questionnaire of joint perception, KOOS, WOMAC and SF-12. RESULTS: Comparison between TKAs and asymptomatic knees revealed that asymptomatic knees had significantly less knee flexion at initial contact (p < 0.04) and more flexion for most of the swing phase (p between 0.004 and 0.04). Asymptomatic knees also had less varus at loading response, during stance phase and during most of the swing phase (p between 0.001 - 0.05). Transverse plane analysis showed a tendency for asymptomatic knees to be more in internal rotation during stance phase (p 0.02 - 0.04). Comparing both TKA designs, Nexgen(TM) implant had significantly more flexion at the end of swing phase (p = 0.04) compared to knees with the Triathlon(TM) implant. In frontal plane, from initial contact to maximum mid stance angle and between the mean mid stance angle and initial contact Nexgen(TM) TKA had significantly more adduction (varus, p =0.02 - 0.03). Clinical scores of both TKAs did not have significant difference. CONCLUSIONS: TKA with the tested implants did not reproduce natural knee kinematics during gait. In our cohort of patients, TKA implant design translated in limited kinematics differences during gait and on clinical results.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.083
Threshold uncertainty score0.507

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.345
Teacher spread0.300 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueThe Open Orthopaedics JournalSame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207