Biosensor Technology and the Clinical Biochemistry Laboratory – Issue of Signal Interference from the Biological Matrix

2013· book-chapter· en· W2412109718 on OpenAlexaff
Michael Thompson, Sonia Sheikh, Christophe Blaszykowski, Alexander D. Romaschin

Bibliographic record

Venuenot available
Typebook-chapter
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced biosensing and bioanalysis techniques
Canadian institutionsSt. Michael's HospitalUniversity of Toronto
Fundersnot available
KeywordsBiosensorClinical biochemistryInterference (communication)Matrix (chemical analysis)NanotechnologySensitivity (control systems)Computer scienceFunction (biology)Biochemical engineeringElectronic engineeringEngineeringChemistryMaterials scienceTelecommunicationsBiologyChromatography

Abstract

fetched live from OpenAlex

This chapter discusses the potential use of biosensor technology in the clinical biochemistry laboratory. Various relevant key aspects of biosensor technology are introduced such as the chemistry of attachment of probes to device surfaces and a summary of the main categories of sensors based on electrochemistry, acoustic-wave physics and optical science. Important performance characteristics of typical clinical measurements are appraised with examples being presented. Following this discussion, the relevant issues of device selectivity, sensitivity, dynamic range and calibration with respect to target concentration, and possibility for label-free operation are evaluated. A critical issue for potential clinical measurement is the mandatory requirement for devices to function in biological fluids and matrices, with avoidance of signal interference caused by nonspecific surface adoption. Solutions for the latter problem are summarized. The chapter closes with a look at the possible features of biosensor technology that could be employed in the clinical biochemistry laboratory.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Theoretical or conceptual · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.013
Threshold uncertainty score0.044

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0030.004
Open science0.0010.001
Research integrity0.0020.004
Insufficient payload (model declined to judge)0.0130.014

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.293
Teacher spread0.277 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designTheoretical or conceptual
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2013
Admission routes1
Has abstractyes

Explore more

Same topicAdvanced biosensing and bioanalysis techniques→French-language works237,207→