MétaCan
Menu
Back to cohort
Record W2412208162 · doi:10.1118/1.1997347

Monte Carlo modeling of the response of NRC's primary beta standard

2005· article· en· W2412208162 on OpenAlexafffundabout
T. Palani Selvam, P.R.B. Saull, D. W. O. Rogers

Bibliographic record

VenueMedical Physics · 2005
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsNational Research Council CanadaCarleton University
FundersNational Research Council CanadaCanada Research Chairs
KeywordsExtrapolationIonization chamberMonte Carlo methodDosimetryPhysicsBETA (programming language)Materials scienceAbsorbed doseRadiationComputational physicsNuclear medicineOpticsNuclear physicsIonizationMathematicsStatisticsIonComputer science

Abstract

fetched live from OpenAlex

The BEAMnrc/EGSnrc Monte Carlo code system is employed to develop a model of the National Research Council of Canada primary standard of absorbed dose to tissue in a beta radiation field, comprising an extrapolation chamber and Sr90∕Y90 beta source. We benchmark the model against the measured response of the chamber in terms of absorbed dose to air, for three different experimental setups when irradiated by the Sr90∕Y90 source. For the first setup, the chamber cavity depth is fixed at 0.2cm and the source-to-chamber distance varied between 11 and 60cm. In the other two cases, the source-to-chamber distance is fixed at 30cm. In one case the response for different chamber depths is studied, while in the other case the chamber depth is fixed at 0.2cm as different thicknesses of Mylar™ are added to the front surface of the extrapolation chamber. The agreement as a function of distance between the calculated and measured responses is within 0.37% for a variation in response of a factor of 29. In the case of dose versus chamber depth, the agreement is within 0.4% for the ISO-recommended nominal depths of 0.025-0.25cm. Agreement between calculated and measured responses is very good (between 0.02% and 0.2%) for added Mylar foils of thicknesses up to 10.8mgcm-2. For larger Mylar thicknesses, deviations of 0.6%-1.2% are observed, which are possibly due to the systematic uncertainties associated with the restricted collisional stopping powers of air or Mylar used in the calculations. We conclude that our simulation model represents the extrapolation chamber and Sr90∕Y90 source with adequate accuracy to calculate correction factors for accurate realization of dose rate to tissue at a depth of 7mgcm-2 in an ICRU tissue phantom, despite the fact that the uncertainties in the physical characteristics of the source leave some uncertainty in certain calculated quantities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.029
Threshold uncertainty score0.057

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.273
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2005
Admission routes3
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207