MétaCan
Menu
Back to cohort
Record W2416718017 · doi:10.5114/jcb.2015.52127

Original paper Evaluation of the dosimetric impact of loss and displacement of seeds in prostate low-dose-rate brachytherapy

2015· article· en· W2416718017 on OpenAlexaff
Yinkun Wang, Nicola J. Nasser, Jette Borg, Elantholi P. Saibishkumar

Bibliographic record

VenueJournal of Contemporary Brachytherapy · 2015
Typearticle
Languageen
FieldMedicine
TopicProstate Cancer Diagnosis and Treatment
Canadian institutionsUniversity of TorontoUniversity Health NetworkPrincess Margaret Cancer Centre
Fundersnot available
KeywordsBrachytherapyMedicineDose rateNuclear medicineProstate brachytherapyDosimetryProstateProstate cancerMedical physicsSurgeryRadiation therapyInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: To analyze the seed loss and displacement and their dosimetric impact in prostate low-dose-rate (LDR) brachytherapy while utilizing the combination of loose and stranded seeds. MATERIAL AND METHODS: Two hundred and seventeen prostate cancer patients have been treated with LDR brachytherapy. Loose seeds were implanted in the prostate center and stranded seeds in the periphery of the gland. Patients were imaged with transrectal ultrasound before implant and with computerized tomography/magnetic resonance imaging (CT/MR) one month after implant. The seed loss and displacement had been analyzed. Their impact on prostate dosimetry had been examined. The seed distribution beyond the prostate inferior boundary had been studied. RESULTS: The mean number of seeds per patient that were lost to lung, pelvis/abdomen, urine, or unknown destinations was 0.21, 0.13, 0.03, and 0.29, respectively. Overall, 40.1% of patients had seed loss. Seed migration to lung and pelvis/abdomen occurred in 15.5% and 10.5% of the patients, respectively. Documented seed loss to urine was found in 3% of the patients while 20% of patients had seed loss to unknown destinations. Prostate length difference between pre-plan and post-implant images was within 6 mm in more than 98% of cases. The difference in number of seeds inferior to prostate between pre-plan and post-implant dosimetry was within 7 seeds for 93% of patients. At time of implant, 98% of seeds, inferior to prostate, were within 5 mm and 100% within 15 mm, and in one month post-implant 83% within 9 mm and 96.3% within 15 mm. Prostate post-implant V100, D90, and rectal wall RV100 for patients without seed loss were 94.6%, 113.9%, and 0.98 cm(3), respectively, as compared to 95.0%, 114.8%, and 0.95 cm(3) for the group with seed loss. CONCLUSIONS: Seed loss and displacement have been observed to be frequent. No correlation between seed loss and displacement and post-plan dosimetry has been reported.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.023
Threshold uncertainty score0.501

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.353
Teacher spread0.306 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Contemporary BrachytherapySame topicProstate Cancer Diagnosis and TreatmentFrench-language works237,207