MétaCan
Menu
Back to cohort
Record W2417291635

Southmedic OxyMask(TM) compared with the Hudson RCI(®) Non-Rebreather Mask(TM): Safety and performance comparison.

2016· article· en· W2417291635 on OpenAlexaboutno aff
Keith Lamb, David J. W. Piper

Bibliographic record

VenuePubMed · 2016
Typearticle
Languageen
FieldMedicine
TopicInfection Control and Ventilation
Canadian institutionsnot available
Fundersnot available
KeywordsTidal volumeExhalationFraction of inspired oxygenVolumetric flow rateVentilation (architecture)MedicineEnvironmental scienceSimulationAnesthesiaComputer scienceRespiratory systemEngineeringMechanical ventilationInternal medicineMechanical engineeringMechanics
DOInot available

Abstract

fetched live from OpenAlex

BACKGROUND: The non-rebreather mask (NRBM) is used for many applications and in many patient care scenarios in which hypoxemia and resultant hypoxia are a concern. The NRBM is a low-flow oxygen delivery system that is easily deployed and capable of delivering a relatively high fraction of inspired oxygen (FiO2).The potential for ineffective carbon dioxide (CO2) removal at low flow rates is a safety concern. OBJECTIVE: The authors hypothesized that the use of an OxyMask (Southmedic Inc, Canada) would mitigate these safety concerns while still delivering a relatively high FiO2. METHODS: Bench studies were performed in a third-party laboratory by qualified engineers (Piper Medical, USA). A Harvard Respirator Pump (Harvard Apparatus, USA), oxygen source, CO2 source and a mannequin head were used to simulate varying respiratory conditions. End tidal CO2 (EtCO2), FiO2, fraction of inspired CO2 and percent drop in CO2 in the first second of exhalation were measured at different mask flow rates and respiratory rates. There were two categories of flow rates: high-flow (15 L/min) and low-flow (2 L/min). In each flow group, the above parameters were measured using a tidal volume of 400 mL, inspiratory/expiratory ratio of 1:2, EtCO2 of 5% and a breathing frequency of 15, 20 or 24 breaths/min. Mask performance measurements were obtained and compared. CONCLUSION: The OxyMask outperformed the traditional NRBM in each tested category. There was a higher inspired oxygen level, lower inspired CO2 level, and more efficient CO2 clearance at each mask flow level and simulated patient minute volume. This was especially true during conditions in which there were very low mask flow rates.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.400
Threshold uncertainty score0.320

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.217
Teacher spread0.201 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2016
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicInfection Control and VentilationFrench-language works237,207