MétaCan
Menu
Back to cohort
Record W2434064051 · doi:10.1111/jvim.14361

Incremental Value (Bayesian Framework) of Thoracic Ultrasonography over Thoracic Auscultation for Diagnosis of Bronchopneumonia in Preweaned Dairy Calves

2016· article· en· W2434064051 on OpenAlexaff
Sébastien Buczinski, Jessie Ménard, Edouard Timsit

Bibliographic record

VenueJournal of Veterinary Internal Medicine · 2016
Typearticle
Languageen
FieldMedicine
TopicUltrasound in Clinical Applications
Canadian institutionsUniversity of CalgaryUniversité de MontréalCegep de Saint Hyacinthe
Fundersnot available
KeywordsMedicineAuscultationBronchopneumoniaConfidence intervalUltrasonographyInternal medicineRadiologyPediatrics

Abstract

fetched live from OpenAlex

BACKGROUND: Thoracic ultrasonography (TUS) is a specific and relatively sensitive method to diagnose bronchopneumonia (BP) in dairy calves. Unfortunately, as it requires specific training and equipment, veterinarians typically base their diagnosis on thoracic auscultation (AUSC), which is rapid and easy to perform. HYPOTHESIS/OBJECTIVES: We hypothesized that the use of TUS, in addition to AUSC, can significantly increase accuracy of BP diagnosis. Therefore, the objectives were to (i) determine the incremental value of TUS over AUSC for diagnosis of BP in preweaned dairy calves and (ii) assess diagnostic accuracy of AUSC. ANIMALS: Two hundred and nine dairy calves (<1 month of age) were enrolled in this cross-sectional study. METHODS: Prospective cross-sectional study. All calves from a veal calves unit were examined (independent operators) using the Wisconsin Calf Respiratory Scoring Criteria (CRSC), AUSC, and TUS. A Bayesian latent class approach was used to estimate the incremental value of AUSC over TUS (integrated discrimination improvement [IDI]) and the diagnostic accuracy of AUSC. RESULTS: Abnormal CRSC, AUSC, and TUS were recorded in 3.3, 53.1, and 23.9% of calves, respectively. AUSC was sensitive (72.9%; 95% Bayesian credible interval [BCI]: 50.1-96.4%), but not specific (53.3%; 95% BCI: 43.3-64.0%) to diagnose BP. Compared to AUSC, TUS was more specific (92.9%; 95% BCI: 86.5-97.1%), but had similar sensitivity (76.5%; 95% BCI: 60.2-88.8%). The incremental value of TUS over AUSC was high (IDI = 43.7%; 5% BCI: 22.0-63.0%) significantly improving proportions of sick and healthy calves appropriately classified. CONCLUSIONS AND CLINICAL IMPORTANCE: The use of TUS over AUSC significantly improved accuracy of BP diagnosis in dairy calves.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.026
metaresearch head score (Gemma)0.088
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.026
Threshold uncertainty score0.136

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0260.088
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.420
Teacher spread0.375 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Veterinary Internal MedicineSame topicUltrasound in Clinical ApplicationsFrench-language works237,207