MétaCan
Menu
Back to cohort
Record W2465433807 · doi:10.6000/1927-5129.2016.12.40

Radiation Dose Distribution Measurements of Kilo-Voltage Photons Using Optically Stimulated Luminescence Detectors (OSLs) in Radiological Procedures

2016· article· en· W2465433807 on OpenAlexvenueno aff
Syed Mansoor Naqvi, Zaheer Uddin, Zafar Sajjad, Imran Siddiqui, Amjad Hussan

Bibliographic record

VenueJournal of Basic & Applied Sciences · 2016
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsnot available
Fundersnot available
KeywordsCollimated lightImaging phantomRadiographyNuclear medicineRadiationX-rayRadiological weaponDetectorMaterials scienceOpticsPhotonPhysicsMedicineRadiologyNuclear physicsLaser

Abstract

fetched live from OpenAlex

OSL detectors were used for dose measurement in a solid water phantom. Two other detectors, Cobia Flex (RTI Electronics) and PTW-Diados were also used to verify the measurements. Radiation doses were measured for a wide range of radiographic techniques and set of parameters from very low (1 mAs, 55 kV) to very high (140 mAs, 120 kV) exposures. Multiple x-ray units were used to ensure that the measured doses are independent of x-ray units and are dependent on the specified radiographic parameters. Measurements were performed at the standard medical radiographic imaging Source-to-Image-Distances (SID) of 100 cm and 180 cm. all the x-ray beams were collimated to produce a 20 cm × 20 cm field size.We measured the radiation doses at different depths and estimated entrance surface doses during common radiological procedures. Measured doses fall exponentially with depths at all energies and exposures. A nonlinear relation is clearly evident between the dose and the x-ray beam energy. The measurements also show that the radiation dose is directly proportional to the exposure. Entrance Surface Doses (ESD) were also measured and found to be as low as 0.119 mGy±0.020 (0.092-0.141) for extremities to as high as 13.083 mGy±3.988(8.246-17.560) to the Spine and Abdomen. ESDs for the chest x-ray were measured to be 0.158 mGy±0.074(0.034-0.275).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.120
Threshold uncertainty score0.283

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.285
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Basic & Applied SciencesSame topicRadiation Detection and Scintillator TechnologiesFrench-language works237,207