MétaCan
Menu
Back to cohort
Record W2465939657 · doi:10.1093/europace/euw116

Wound haematoma following defibrillator implantation: incidence and predictors in the Shockless Implant Evaluation (SIMPLE) trial

2016· article· en· W2465939657 on OpenAlexaff
Simona Masiero, Stuart J. Connolly, David Birnie, Jörg Neuzner, Stefan H. Hohnloser, Xavier Viñolas, Josef Kautzner, Gilles O’Hara, Lieselot VanErven, Fredrik Gadler, Jia Wang, Philippe Mabo, Michael Glikson, Valentina Kutyifa, David J. Wright, Vidal Essebag, Jeff S. Healey

Bibliographic record

VenueEP Europace · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsMcGill UniversityInstitut universitaire de cardiologie et de pneumologie de QuébecUniversity of OttawaMcMaster UniversityPopulation Health Research Institute
Fundersnot available
KeywordsMedicineAtrial fibrillationImplantStroke (engine)SurgeryComplicationImplantable cardioverter-defibrillatorHematomaIncidence (geometry)HeparinLow molecular weight heparinInternal medicineCardiology

Abstract

fetched live from OpenAlex

AIMS: Pocket haematoma is a common complication after defibrillator [implantable cardioverter defibrillator (ICD)] implantation, which is not only painful, but also increases the risk of device-related infection, and possibly embolic events. The present study seeks to evaluate the rate and predictors of clinically significant pocket haematoma. METHODS AND RESULTS: This study included 2500 patients receiving an ICD in the SIMPLE trial. A clinically significant pocket haematoma was defined as a haematoma that required re-operation or interruption of oral anticoagulation (OAC) therapy. Clinically significant pocket haematoma occurred in 56 of 2500 patients (2.2%) of which 6 (10.7%) developed device-related infection. Patients who developed pocket haematoma were older (mean age 67.6 ± 8.8 years vs. 62.7 ± 11.6 years, P < 0.001), were more likely to have permanent atrial fibrillation (30.4 vs. 6.7%, P < 0.001) and a history of stroke (17.9 vs. 6.7%, P = 0.004), or were more likely to receive peri-operative OAC (50.0 vs. 28.4%, P < 0.001), unfractionated heparin (16.1 vs. 5.2%, P = 0.003), or low-molecular-weight heparin (37.5 vs. 17.5%, P < 0.001). Independent predictors of wound haematoma on multivariable analysis included the use of heparin bridging (OR 2.65, 95% CI 1.48-4.73, P = 0.001), sub-pectoral location of ICD (OR 2.00, 95% CI 1.12-3.57, P =0.020), previous stroke (OR 2.47, 95% CI 1.20-5.10, P = 0.015), an upgrade from permanent pacemaker (OR 2.52, 95% CI 1.07-5.94, P = 0.035), and older age (OR 1.03, 95% CI 1.00-1.06, P = 0.049). CONCLUSION: Pocket haematoma remains an important complication of ICD implantation and is associated with a high risk of infection. Independent predictors of pocket haematoma include heparin bridging, prior stroke, sub-pectoral placement of ICD, older age, and upgrade from a pacemaker.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.034
Threshold uncertainty score0.346

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.331
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations33
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueEP EuropaceSame topicCardiac pacing and defibrillation studiesFrench-language works237,207