MétaCan
Menu
Back to cohort
Record W2472428079

Total Hip Arthroplasty Following Failure of Core Decompression and Tantalum Rod Insertion for Femoral Head Avascular Necrosis

2013· article· en· W2472428079 on OpenAlexaff
Michael Olsen, Peter L. Lewis, Ryan Wolek, Michael D. McKee, James P. Waddell, Emil H. Schemitsch

Bibliographic record

VenueJournal of Bone and Joint Surgery-british Volume · 2013
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsFemoral headAvascular necrosisMedicineSurgeryTantalumTotal hip arthroplastyRadiographyDecompressionArthroplastyNuclear medicineMaterials science
DOInot available

Abstract

fetched live from OpenAlex

Introduction: One method of femoral head preservation following avascular necrosis (AVN) is core decompression and Tantalum Rod insertion. There is, however, a published failure rate of up to 32% at 4 years. The purpose of the present study was to document the clinical and radiological outcome following Total Hip Arthroplasty (THA) subsequent to failed Tantalum Rod insertion. Methods: Twenty-five failed Tantalum Rod insertions subsequently requiring THA were identified from a prospectively updated database. Seventeen patients met minimum 2 year clinical and radiographic follow-up criteria. St. Michael9s Hip (SMH) scores were compared to a matched cohort of patients with THA for AVN without prior Tantalum Rod insertion. Postoperative radiographs were reviewed assessing component alignment, linear wear (Dorr & Wan) and presence of tantalum residue within the joint space. Results: Nine females and eight males underwent removal of a Tantalum Rod with subsequent THA between May 2005 and March 2010. The mean time between Tantalum Rod insertion and conversion to THA was 23 months (range 6–48) with a mean follow-up of 3.5 years (range 2–5). At each follow-up interval the mean SMH scores were comparable between the two groups (p = 0.445). Femoral stem alignment (p = 0.428) and acetabular cup inclination (p = 0.723) were comparable between groups. Articular tantalum residue was identified in 12 of 17 articulations (7 mild, 3 moderate, 2 severe). Linear wear rates were comparable between the tantalum group (0.07 mm/yr, range 0.01–0.40) and controls (0.07 mm/yr, range 0.02–0.21, p = 0.951). There was no evidence of catastrophic wear. Conclusion: Tantalum rod conversion to THA in the young adult patient with AVN reveals no early catastrophic sequelae. In the short term, Tantalum Rod insertion does not demonstrate a deleterious effect on subsequent total joint replacement surgery. There is, however, a high rate of retained tantalum debris within the effective joint space with the procedure and thus there is an unknown risk of accelerated articular wear necessitating longer term study.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.237
Threshold uncertainty score0.663

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.242
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Bone and Joint Surgery-british VolumeSame topicOrthopaedic implants and arthroplastyFrench-language works237,207