TU-AB-BRC-03: Accurate Tissue Characterization for Monte Carlo Dose Calculation Using Dual-and Multi-Energy CT Data
Bibliographic record
Abstract
Purpose: To develop a general method for human tissue characterization with dual-and multi-energy CT and evaluate its performance in determining elemental compositions and the associated proton stopping power relative to water (SPR) and photon mass absorption coefficients (EAC). Methods: Principal component analysis is used to extract an optimal basis of virtual materials from a reference dataset of tissues. These principal components (PC) are used to perform two-material decomposition using simulated DECT data. The elemental mass fraction and the electron density in each tissue is retrieved by measuring the fraction of each PC. A stoichiometric calibration method is adapted to the technique to make it suitable for clinical use. The present approach is compared with two others: parametrization and three-material decomposition using the water-lipid-protein (WLP) triplet. Results: Monte Carlo simulations using TOPAS for four reference tissues shows that characterizing them with only two PC is enough to get a submillimetric precision on proton range prediction. Based on the simulated DECT data of 43 references tissues, the proposed method is in agreement with theoretical values of protons SPR and low-kV EAC with a RMS error of 0.11% and 0.35%, respectively. In comparison, parametrization and WLP respectively yield RMS errors of 0.13% and 0.29% on SPR, and 2.72% and 2.19% on EAC. Furthermore, the proposed approach shows potential applications for spectral CT. Using five PC and five energy bins reduces the SPR RMS error to 0.03%. Conclusion: The proposed method shows good performance in determining elemental compositions from DECT data and physical quantities relevant to radiotherapy dose calculation and generally shows better accuracy and unbiased results compared to reference methods. The proposed method is particularly suitable for Monte Carlo calculations and shows promise in using more than two energies to characterize human tissue with CT.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".