MétaCan
Menu
Back to cohort
Record W2474606013 · doi:10.1093/eurheartj/ehw225

Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of severe aortic stenosis: a meta-analysis of randomized trials

2016· review· en· W2474606013 on OpenAlexaff
George C.M. Siontis, Fabien Praz, Thomas Pilgrim, Dimitris Mavridis, Subodh Verma, Georgia Salanti, Lars Søndergaard, Peter Jüni, Stephan Windecker

Bibliographic record

VenueEuropean Heart Journal · 2016
Typereview
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversity of TorontoSt. Michael's Hospital
Fundersnot available
KeywordsMedicineStenosisAortic valve replacementAortic valve stenosisCardiologyAortic valveInternal medicineMeta-analysisRandomized controlled trialSurgeryValve replacement

Abstract

fetched live from OpenAlex

In view of the currently available evidence from randomized trials, we aimed to compare the collective safety and efficacy of transcatheter aortic valve implantation (TAVI) vs. surgical aortic valve replacement (SAVR) across the spectrum of risk and in important subgroups. Trials comparing TAVI vs. SAVR were identified through Medline, Embase, and Cochrane databases. The primary outcome was death from any cause at 2 years. We performed random-effects meta-analyses to combine the available evidence and to evaluate the effect in different subgroups. This systematic review and meta-analysis is registered with PROSPERO (CRD42016037273). We identified four eligible trials including 3806 participants, who were randomly assigned to undergo TAVI (n = 1898) or SAVR (n = 1908). For the primary outcome of death from any cause, TAVI when compared with SAVR was associated with a significant 13% relative risk reduction [hazard ratio (95% CI): 0.87 (0.76–0.99); P = 0.038] with homogeneity across all trials irrespective of TAVI device (Pinteraction = 0.306) and baseline risk (Pinteraction = 0.610). In subgroup analyses, TAVI showed a robust survival benefit over SAVR for patients undergoing transfemoral access [0.80 (0.69–0.93); P = 0.004], but not transthoracic access [1.17 (0.88–1.56); P = 0.293] (Pinteraction = 0.024) and in female [0.68 (0.50–0.91); P = 0.010], but not male patients [0.99 (0.77–1.28); P = 0.952] (Pinteraction = 0.050). Secondary outcomes of kidney injury, new-onset atrial fibrillation, and major bleeding favoured TAVI, while major vascular complications, incidence of permanent pacemaker implantation, and paravalvular regurgitation favoured SAVR. Compared with SAVR, TAVI is associated with a significant survival benefit throughout 2 years of follow-up. Importantly, this superiority is observed irrespective of the TAVI device across the spectrum of intermediate and high-risk patients, and is particularly pronounced among patients undergoing transfemoral TAVI and in females.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.014
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.011
Threshold uncertainty score0.038

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0070.014
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0110.021
Bibliometrics0.0020.003
Science and technology studies0.0000.000
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.173
GPT teacher head0.448
Teacher spread0.274 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations362
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Heart JournalSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207