MétaCan
Menu
Back to cohort
Record W2482734106 · doi:10.1007/s12630-016-0706-y

Comparison of isoflurane and sevoflurane in cardiac surgery: a randomized non-inferiority comparative effectiveness trial

2016· article· en· W2482734106 on OpenAlexafffund
Philip M. Jones, Daniel Bainbridge, Michael Chu, Philip Fernandes, Stephanie A. Fox, Iván Iglesias, Bob Kiaii, Ronit Lavi, John M. Murkin

Bibliographic record

VenueCanadian Journal of Anesthesia/Journal canadien d anesthésie · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiac Ischemia and Reperfusion
Canadian institutionsLondon Health Sciences CentreWestern University
FundersAcademic Medical Organization of Southwestern Ontario
KeywordsMedicineSevofluraneIsofluraneAnesthesiaRandomized controlled trialIntensive care unitCoronary artery bypass surgeryConfidence intervalClinical trialCardiac surgeryAnestheticSurgeryArteryInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: Volatile anesthetics possess cardioprotective properties, but it is unknown if the cardioprotective effects extend equally to all members of the class. Although sevoflurane is a relatively newer anesthetic than isoflurane, its introduction into practice was not preceded by a head-to-head comparison with isoflurane in a trial focusing on clinically important outcomes. Our objective was to determine whether sevoflurane was non-inferior to isoflurane on a clinically important primary outcome in a heterogeneous group of adults undergoing cardiac surgery. METHODS: This was a pragmatic randomized non-inferiority comparative effectiveness clinical trial in 464 adults having coronary artery bypass graft and/or single valve surgery during November 2011 to March 2014. The intervention was maintenance of anesthesia with sevoflurane (n = 231) or isoflurane (n = 233) administered at a dose of 0.5-2.0 MAC throughout the entire operation. All caregivers were blinded except for the anesthesiologist and perfusionist. The primary outcome was a composite of intensive care unit (ICU) length of stay ≥ 48 hr and all-cause 30-day mortality. We hypothesized that sevoflurane would be non-inferior to isoflurane (non-inferiority margin < 10% based on an expected event rate of 25%). Secondary outcomes included prolonged ICU stay, 30- and 365-day all-cause mortality, inotrope or vasopressor usage, new-onset hemodialysis or atrial fibrillation, stroke, and readmission to the ICU. RESULTS: No losses to follow-up occurred. The primary outcome occurred in 25% of sevoflurane patients and 30% of isoflurane patients (absolute difference, -5.4%; one-sided 95% confidence interval, 1.4), thus non-inferiority was declared. Sevoflurane was not superior to isoflurane for the primary outcome (P = 0.21) or for any secondary outcomes. CONCLUSION: Sevoflurane is non-inferior to isoflurane on a composite outcome of prolonged ICU stay and all-cause 30-day mortality. Sevoflurane is not superior to isoflurane on any other of the clinically important outcomes. This trial was registered at clinicaltrials.gov; NCT01477151.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.016
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.057

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0110.016
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0050.004
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0020.002
Open science0.0010.001
Research integrity0.0040.003
Insufficient payload (model declined to judge)0.0060.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.281
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations35
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Journal of Anesthesia/Journal canadien d anesthésieSame topicCardiac Ischemia and ReperfusionFrench-language works237,207