Feature-Based Bi-Planar RSA for Kinematic Analysis of Total Knee Arthroplasty
Bibliographic record
Abstract
Introduction The most common method for accurate kinematic analysis of the knee arthroplasty uses bi-planar fluoroscopy and model-based RSA. The main challenge is to have access to reverse-engineered CAD models of the implant components, if not provided by the company, making this method impractical for a clinical study involving many types or sizes of implants. An alternative could be to reconstruct the 3D primitive features of the implant, such as cylindrical pegs, flat surfaces and circular boundaries, based on their 2D projections. This method was applied by Kaptein et al. (2006) for hip implants. However, despite its broad potential, it has not yet been applied for studying TKA kinematics. This study develops a methodology for feature-based RSA of TKA and investigates the range of accuracies in comparison to model-based RSA. Methods Joint-3D software was developed in the MATLAB programming language to segment and fit elementary 2D features such as circles, lines, and ellipses to the edges of the parts on the radiographs (Figure 1). The software has the capability to reconstruct the 3D location and orientation of the components based on their 2D projections. To test the accuracy of the system a standard primary knee replacement system (Zimmer NexGen) was implanted on bone replica models, and positioned at 0° to 120° flexion at 30° intervals, simulating a lunge activity. For each pose, a multi-planar radiography system developed in our lab (Amiri et al., 2011) was used to take a sagittal and a 15° distally rotated radiograph (Figure 2a). Figure 1 shows the features C, L, and E segmented on the tibia and femur. The 3D reconstruction is performed based on a number of functions: Functions ‘ f ’ and ‘g’ reconstruct a 3D point or line based on their 2D projections. Function ‘ h ’ finds the plane containing the 3D circular edge based on its two projection ellipses. Function ‘ i ’ finds the 3D location of a line based on one projection line, and a known 3D vector normal to the solution 3D line. Based on these, the coordinate systems of the components were reconstructed (Figure 2b): Femur_Origin=f(C1A,C1B); Femur_Anteroposterior=g(L1A, L1B); Femur_Proximodistal=g(L2A,L2B); Femur_Mediolateral=i(L,C1A–C1B),{L=L1: if flexion 45°}; E_3D=h(E1A,E1B); Tibia_Origin=f(E1A_Centre,E1B_Centre); Tibia_Anteroposterior=g(L3A,L3B); Tibia_Mediolateral=cross(E_3D, Tibia_Anteroposterior); Tibia_Proximodistal=cross(Tibia_Anteroposterior, Tibia_Mediolateral) To determine the errors, model-based RSA measures were used as the reference using the reverse-engineered models of the components in JointTrack software (University of Florida). Results The overall accuracies in terms of bias (the mean error) and precision (standard deviation of the errors) are shown in Figure 3. The bias was within 0.5–1 mm and 0.9–1.2°, and the calculated precision was in the range of 0.4–0.6 mm and 0.7–1.0°. The overall accuracy was 0.8±0.6 mm and 1±0.7°. Discussion The very good accuracies obtained show the practicality of the methodology. The methodology can be easily worked out for any type of implant based on the primitive geometric features at the bone-implant interface. This method can be extremely useful in a large clinical study by eliminating the need for having the 3D models of many types and sizes of the implant available.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.004 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.007 | 0.002 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".