MétaCan
Menu
Back to cohort

Impact of Room Supply Register Location on Predicted Thermal Comfort and IAQ

2012· article· en· W2485422310 on OpenAlex
Boualem Ouazia, Iain Macdonald, Alexandra E. Thompson, Daniel Booth

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueInternational Journal of Ventilation · 2012
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsNational Research Council Canada
FundersNatural Resources CanadaNational Research Council CanadaAustralian Government
KeywordsGlazingDuct (anatomy)Thermal comfortIndoor air qualityThermalArchitectural engineeringRoom air distributionEnvironmental scienceAir changeEngineeringWindow (computing)Operative temperatureAutomotive engineeringSimulationMechanical engineeringCivil engineeringMeteorologyComputer scienceEnvironmental engineeringVentilation (architecture)

Abstract

fetched live from OpenAlex

For residential forced air heating and cooling systems conventional thinking is that air supply registers should be located under exterior windows. There were good reasons for this in the past (primarily to counteract the cold downdraught from the window) but new construction standards (well-insulated walls, better glazing and air tight wall/window interface) mean that there is now less downdraught. Positioning the supply air register away from a window could have a large impact for new construction as duct lengths could be shortened (saving materials and construction time). This could also allow greater architectural freedom as the forced air system would not need to be ducted to the building perimeter. This paper presents results from experiments conducted in a new, well-constructed building to evaluate whether the supply registers can be moved away from the traditional location without impacting indoor air quality or predicted thermal comfort. The physical experiments showed that in both traditional and non-traditional placement: (1) there are minimal changes in predicted thermal comfort (a measure of thermal discomfort - vertical air temperature difference much lower than 3K), and (2) contaminant-removal effectiveness (a measure of indoor air quality) values were in the same range.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.779
Threshold uncertainty score0.221

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.254
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it