MétaCan
Menu
Back to cohort
Record W2489543951 · doi:10.1097/mcc.0000000000000344

Assessment of adequacy of volume resuscitation

2016· review· en· W2489543951 on OpenAlexafffund
John H. Boyd, Demetrios Sirounis

Bibliographic record

VenueCurrent Opinion in Critical Care · 2016
Typereview
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsSt. Paul's HospitalUniversity of British Columbia
FundersCanadian Institutes of Health Research
KeywordsMedicineResuscitationVolume (thermodynamics)Intensive care medicineEmergency medicine

Abstract

fetched live from OpenAlex

PURPOSE OF REVIEW: It has recently become evident that administration of intravenous fluids following initial resuscitation has a greater probability of producing tissue edema and hypoxemia than of increasing oxygen delivery. Therefore, it is essential to have a rational approach to assess the adequacy of volume resuscitation. Here we review passive leg raising (PLR) and respiratory variation in hemodynamics to assess fluid responsiveness. RECENT FINDINGS: The use of ultrasound enhances the clinician's ability to detect and predict fluid responsiveness, whereas enthusiasm for this modality must be tempered by recent evidence that it is only reliable in apneic patients. SUMMARY: The best predictor of fluid response for hypotensive patients not on vasopressors is a properly conducted passive leg raise maneuver. For more severely ill patients who are apneic, mechanically ventilated and on vasopressors, point of care echocardiography is the best choice. Increases in vena caval diameter induced by controlled positive pressure breaths are insensitive to arrhythmias and can be performed with relatively brief training. Most challenging are patients who are awake and on vasopressors; we suggest that the best method to discriminate fluid responders is PLR measuring changes in cardiac output.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.004
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.007
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0040.001
Bibliometrics0.0040.002
Science and technology studies0.0000.001
Scholarly communication0.0020.002
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.247
GPT teacher head0.558
Teacher spread0.311 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2016
Admission routes2
Has abstractyes

Explore more

Same venueCurrent Opinion in Critical CareSame topicHemodynamic Monitoring and TherapyFrench-language works237,207