MétaCan
Menu
Back to cohort
Record W2491410634 · doi:10.1186/s12938-016-0205-y

Interference between surgical magnetic drapes and pacemakers: an observational study comparing commercially available devices and a new magnetically isolated drape

2016· article· en· W2491410634 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueBioMedical Engineering OnLine · 2016
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsCégep de Rivière-du-LoupUniversité de MontréalHôpital Maisonneuve-Rosemont
Fundersnot available
KeywordsMagnetInterference (communication)Magnetic noiseElectromagnetic interferenceBiomedical engineeringMedicineMagnetic fieldElectrical engineeringPhysicsEngineering

Abstract

fetched live from OpenAlex

BACKGROUND: Magnetic fields may potentially interfere with the function of cardiovascular implantable electronic devices. Sterile magnetic drapes used to hold surgical instruments are often placed on the patient's thorax, and they are likely to interfere with the function of these devices. METHODS: Thirty patients were recruited to compare a new prototype surgical magnetic drape (LT10G™ by Menodys) made with bottom-isolated ferrite magnets to the Covidien magnetic drape we used in a previous study. Twenty additional patients were recruited to compare the prototype drape with four commercially available surgical magnetic drapes. RESULTS: Magnetic interference was found in 33 of the 50 total patients (70 %) when the Covidien drape was placed over the pacemaker. Of the 20 additional patients, 5 patients (25 %) displayed magnetic interference with a second type of surgical magnetic drape. A third magnetic drape caused interference in one patient (5 %), whereas a larger drape of the same model did not interfere in any patient. No patients demonstrated magnetic interference with the prototype drape. CONCLUSION: Bottom isolation of magnets in the prototype magnetic drape (LT10G™) used during surgery prevents magnetic interference in all patients when placed over the pacemaker. Three of the four commercially available magnetic drapes tested demonstrated magnetic interference. Flipping the prototype drape is not recommended as it may expose non-isolated magnets to the cardiovascular implantable electronic device.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.051
Threshold uncertainty score0.637

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.137
GPT teacher head0.336
Teacher spread0.199 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it