MétaCan
Menu
Back to cohort
Record W2508104454 · doi:10.2319/02016-101.1

Orthodontically induced external apical root resorption in patients treated with fixed appliances vs removable aligners

2016· article· en· W2508104454 on OpenAlexaff
Alejandro Iglesias‐Linares, Boris Sonnenberg, Beatriz Solano, Rosa-María Yáñez-Vico, E. Solano, Steven J. Lindauer, Carlos Flores‐Mir

Bibliographic record

VenueThe Angle Orthodontist · 2016
Typearticle
Languageen
FieldDentistry
TopicOrthodontics and Dentofacial Orthopedics
Canadian institutionsUniversity of Alberta
FundersEuropean Regional Development FundInstituto de Salud Carlos III
KeywordsMedicineDentistryOdds ratioRoot resorptionOrthodonticsConfidence intervalInternal medicineResorption

Abstract

fetched live from OpenAlex

OBJECTIVE: To determine whether orthodontic treatment with removable aligners vs fixed orthodontic appliances is associated with a different frequency of orthodontically induced external apical root resorption (OIEARR) when genetic, radiographic, and clinical factors are accounted for. MATERIALS AND METHODS: Three hundred seventy-two orthodontic patients treated with removable aligners (Invisalign) or fixed appliances were genetically screened for interleukin 1B gene (IL1B) (rs1143634), interleukin 1 receptor antagonist gene (IL1RN) (rs419598), and osteopontin gene (SPP1) (rs9138/rs11730582). Twelve clinical variables, potentially associated with OIEARR, were also considered. Subjects were divided according to the presence of radiographically determined OIEARR (>2 mm). The association between OIEARR and appliance type, and radiographic, clinical and genetic factors, was assessed using backward stepwise conditional logistic regression. Odds ratios (ORs) and 95% confidence intervals (CIs) were reported. RESULTS: Reliability of the methods was adequate. Clinical case complexity (American Board of Orthodontics [ABO] Discrepancy Index) (OR: 1.032; 95% CI: 1.005-1.061; P = .021) and extent of incisor apical displacement in the sagittal plane (OR: 1.478; 95% CI: 1.285-1.699; P = .001) were associated with an increased OIEARR risk. After adjusting for associations between clinical/radiographic/genetic factors, there were no statistically significant differences with respect to OIEARR or type of orthodontic appliance used, whether removable aligners or fixed appliances (OR: 1.662; 95% CI: 0.945-2.924; P = .078). Only subjects homozygous for the T allele of IL1RN (rs419598) were more prone to OIEARR during orthodontic treatment (OR: 3.121; CI: 1.93-5.03; P < .001). CONCLUSIONS: A similar OIEARR predisposition was identified using either removable aligners (Invisalign) or fixed appliances.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.260
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations83
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueThe Angle OrthodontistSame topicOrthodontics and Dentofacial OrthopedicsFrench-language works237,207